A new and rapid on-line preconcentration and matrix separation method is described for the determination of aluminium by flame atomic absorption spectrometry (FAAS) and inductively coupled plasma mass spectrometry (ICP-MS). The method is based on selective retention of aluminium in a microcolumn pac
Coupled flow-injection analysis-flame atomic absorption spectrometry for the quantitative determination of aluminium in beverages and waters incorporating on-line cation exchange
✍ Scribed by Henryk J. Salacinski; Philip G. Riby; Stephen J. Haswell
- Publisher
- Elsevier Science
- Year
- 1992
- Tongue
- English
- Weight
- 577 KB
- Volume
- 269
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
✦ Synopsis
A method for determmmg the alunumum levels m local water, tea leaf digest, tea and coffee mfuslons by means of on-hne cation exchange flow-mlectlon-flame atomic absorptron spectrometry (FIA-FAAS) IS described Quantltatwe results can be carried out down to 7.5 ng ml -' of Al usmg sample volumes III the range 6 O-24 0 ml The method using a conventIona FAAS system was found to be rapid, simple and relatwely mexpenswe offermg good selectlvlty and typlcal R S D s of l-2% (n = 10) with a relatwe error of about 2%
📜 SIMILAR VOLUMES
## Abstract Inorganic mercury and methylmercury are determined in natural waters by injecting the filtered samples onto a low cost commercial flow injection system in which an anion exchange microcolumn is inserted after the injection loop (FIA‐IE). If hydrochloric acid is used as the carrier solut
A flow injection on-line sorbent extraction system was studied in conjunction with flame atomic absorption spectrometry to determine cadmium, copper and lead in digest solutions of solid environmental samples using octadecyl functional groups (C,,) bonded silica gel as sorbent with diethylammonium-Z
A flow-injection on-I& adsorption precontentration flame atomic absorption spectrometric system for the detenninatian of copper was developed. The copper d~eth~ldith~~arba~ate chefate was adsorbed on the walls of a PTFE knotted reactor. The sorbed species was eluted by isobutyl methyl ketone at a fl
An automated robotic method for sample pretreatment was developed for copper determination in environmental and biological materials at the low microgram per gram level. The robotic station performing the preliminary operations as weighing of sample and acid digestion was coupled with the flowinject
A flow-injection on-line 8531 fibre column separation and preconcentration system is proposed for the efficient flame atomic absorption spectrometric determination of trace gold in ores and metallurgical samples. A flow manifold with a pump and two valves was assembled to conduct the operating cycle