𝔖 Bobbio Scriptorium
✦   LIBER   ✦

On-line preconcentration of aluminium with immobilized Chromotrope 2B for the determination by flame atomic absorption spectrometry and inductively coupled plasma mass spectrometry

✍ Scribed by A. Martín-Esteban; P. Fernández; C. Pérez-Conde; A. Gutiérrez; C. Cámara


Publisher
Elsevier Science
Year
1995
Tongue
English
Weight
437 KB
Volume
304
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


A new and rapid on-line preconcentration and matrix separation method is described for the determination of aluminium by flame atomic absorption spectrometry (FAAS) and inductively coupled plasma mass spectrometry (ICP-MS). The method is based on selective retention of aluminium in a microcolumn packed with Chromotrope 2B immobilized on AG l-X8 ion exchange resin. All the variables that affect the efficiency of aluminium retention and elution from the microcolumn have been investigated. The resulting method is rapid, sensitive and selective. For collection times of 10 and 2 min at a flow rate of 1 ml min-' the detection limits are 10 and 0.1 ng ml-' for FAAS and ICP-MS, respectively. The proposed method, which is highly sensitive and selective, was successfully applied to determine aluminium in tap water and dialysis solutions.


📜 SIMILAR VOLUMES


Inductively coupled plasma mass spectrom
✍ Masahito Higashiura; Hiroshi Uchida; Tetsuo Uchida; Hiroko Wada 📂 Article 📅 1995 🏛 Elsevier Science 🌐 English ⚖ 428 KB

Three analytical methods for the determination of gold in the serum of rheumatoid patients have been compared, i.e., flame and graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry (ICP-MS) with the respective detection limits of 30, 1.0 and 0.01 ng ml-'. T

Copper determination by flow injection o
✍ Akbar Ali; Hong Shen; Xue Gu; Guangming Xu; Yingxue Ye; Xuefeng Yin 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 144 KB 👁 2 views

1,10 Phenanthroline (phen) has been tested as a complexing agent, which is more stable and selective than sodium-diethyldithiocarbamate (DDTC) and ammonium-pyrrolidinedithiocarbamate (APDC), for on-line preconcentration of copper on RP-C 18 material in a microcolumn with a flow injection-flame atomi

Determination of Cd, Co, Cu, Mn, Ni, Pb,
✍ A. Bortoli; M. Gerotto; M. Marchiori; F. Mariconti; M. Palonta; A. Troncon 📂 Article 📅 1996 🏛 Elsevier Science 🌐 English ⚖ 98 KB

The concentrations of Cd, Co, Cu, Mn, Ni, Pb, and Zn in natural and sea waters are too low to be directly determined with by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GFAAS). Specific sample preparations are requested that make possible the deter

Robotic sample pretreatment coupled with
✍ Alfredo Velasco-Arjona; María Dolores Luque de Castro; Elissaveta Ivanova; Fredd 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 172 KB 👁 2 views

An automated robotic method for sample pretreatment was developed for copper determination in environmental and biological materials at the low microgram per gram level. The robotic station performing the preliminary operations as weighing of sample and acid digestion was coupled with the flowinject

Extracting stoichiometry, thermodynamics
✍ Yan Li; Yun-Long Xia; Yan Jiang; Xiu-Ping Yan 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 340 KB 👁 1 views

## Abstract Understanding the binding of cadmium with DNA is of great importance for elucidating the mechanism of cadmium genotoxicity and carcinogenicity. In the present work, CE on‐line coupled with electrothermal atomic absorption spectrometry was employed to study the binding electrophoretic be