๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Use of a tilted double clamp in microvascular anastomosis

โœ Scribed by P. M. Hendel; Dr. Harry J. Buncke


Publisher
John Wiley and Sons
Year
1980
Tongue
English
Weight
248 KB
Volume
1
Category
Article
ISSN
0738-1085

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

A tilted or angulated double microvascular clamp is described that, when applied to the vessels to be anastomosed, presents the vessel ends angulated upward facing the surgeon, so that the initial suturing of the posterior wall can be completed without rotating the vessel. Such a clamp is valuable in clinical situations where space is limited and where conventional double clamps cannot be rotated in the usual fashion.


๐Ÿ“œ SIMILAR VOLUMES


A new approximator used in microvascular
โœ Memet Yazar; Karaca Basaran; Erdem Guven; Alper Mete Ugurlu; Murat Topalan ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 256 KB

Microsurgery is a valuable discipline performed in many surgical practices. In literature, hundreds of studies dealing with different aspects of microsurgical practice including studies about new agents for anastomosis, different suturing materials and methods plus new models for surgical training,

Calculation of overall tilt angles for a
โœ Dr. Patrick M. Kelly; Corinna J. Wauchope; Xuezhi Zhang ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 405 KB

A simple formula has been derived for the tilt angle of a specimen in terms of the two tilt angles of a side entry, double tilt holder in a transmission electron microscope. An expression for calculating the direction of the apparent tilt axis in relation to the observed diffraction pattern has also

A comparison of continuous with interrup
โœ Dr. Kenneth Mao; Mai Y. M. Tang; John Roger South ๐Ÿ“‚ Article ๐Ÿ“… 1986 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 251 KB

Microvascular anastomoses were performed on rat common carotid arteries using either continuous or interrupted sutures. The contralateral common carotid artery was ligated to create a demand situation. At 6 months, there was no statistically significant difference between the diameters of vessels an

Gain clamping in double-pass L-band EDFA
โœ S. W. Harun; N. MD Samsuri; H. Ahmad ๐Ÿ“‚ Article ๐Ÿ“… 2004 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 98 KB

## Abstract A gainโ€clamped longโ€wavelengthโ€band erbiumโ€doped fiber amplifier (Lโ€band EDFA) based on a ringโ€laser cavity is demonstrated using two C/Lโ€band wavelengthโ€selective couplers. This new design provides improved gain characteristics and high tuneability. The gain is clamped at 11.5 dB with