𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Time-resolved contrast-enhanced carotid imaging using undersampled projection reconstruction acquisition

✍ Scribed by Jiang Du; Sean B. Fain; Frank R. Korosec; Thomas M. Grist; Charles A. Mistretta


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
691 KB
Volume
25
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To investigate the utility of nonuniform angular spacing of projections in a three‐dimensional (3D) hybrid undersampled projection reconstruction (PR) acquisition for contrast‐enhanced (CE) time‐resolved carotid imaging.

Materials and Methods

Carotid CE magnetic resonance angiography (CE‐MRA) was performed on seven healthy volunteers using a time‐resolved hybrid sequence that combined undersampled PR acquisition in‐plane and Cartesian slice encoding through‐plane. The undersampling streak artifact comes mainly from the superior–inferior (S/I) direction in carotid imaging and is suppressed by nonuniform distribution of the projections. Phantom and volunteer studies were performed to demonstrate its efficacy.

Results

The undersampling streak artifact was significantly suppressed through a nonuniform distribution of the projection angles with more projections aligned along the S/I direction. The hybrid PR sequence combined with nonuniform distribution of the projection angles provided time‐resolved images of the carotid arteries with high temporal resolution (two seconds per frame) and high spatial resolution (1.0 × 1.0 × 1.5 mm^3^) simultaneously.

Conclusion

High‐resolution dynamic imaging of the carotid arteries is feasible with the use of a hybrid undersampled PR acquisition. Undersampling streak artifact can be suppressed significantly through nonuniform distribution of the projections. J. Magn. Reson. Imaging 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Undersampled projection-reconstruction i
✍ Karl K. Vigen; Dana C. Peters; Thomas M. Grist; Walter F. Block; Charles A. Mist 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 300 KB

In time-resolved contrast-enhanced 3D MR angiography, spatial resolution is traded for high temporal resolution. A hybrid method is presented that attempts to reduce this tradeoff in two of the spatial dimensions. It combines an undersampled projection acquisition in two dimensions with variable rat

Contrast-enhanced peripheral magnetic re
✍ Jiang Du; Timothy J. Carroll; Ethan Brodsky; Aiming Lu; T.M. Grist; Charles A. M 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 528 KB

## Abstract ## Purpose To investigate the application of time‐resolved vastly undersampled isotropic projection reconstruction (VIPR) in contrast‐enhanced magnetic resonance angiography of the distal extremity (single station), and peripheral run‐off vasculature in the abdomen, thigh, and calf (th

Time-resolved undersampled projection re
✍ Jiang Du; Aiming Lu; Walter F. Block; Francis J. Thornton; Thomas M. Grist; Char 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 428 KB

## Abstract The hybrid projection reconstruction (PR) imaging provides high temporal resolution through an undersampled PR acquisition for the in‐plane dimensions and Cartesian slice encoding for the through‐plane dimension. The undersampling of projection data introduces streak artifact, which may

Time-resolved contrast-enhanced imaging
✍ Andrew V. Barger; Walter F. Block; Yuriy Toropov; Thomas M. Grist; Charles A. Mi 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 768 KB

Time-resolved contrast-enhanced 3D MR angiography (MRA) methods have gained in popularity but are still limited by the tradeoff between spatial and temporal resolution. A method is presented that greatly reduces this tradeoff by employing undersampled 3D projection reconstruction trajectories. The v

Adaptive bilateral breast MRI using proj
✍ E. Ramsay; P. Causer; K. Hill; D. Plewes 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 619 KB

## Abstract ## Purpose To introduce a bilateral implementation of an adaptive imaging technique in which both dynamic and high resolution breast MR images are acquired simultaneously. ## Materials and Methods Adaptive three‐dimensional bilateral breast imaging in the sagittal plane was achieved

Time-resolved, undersampled projection r
✍ J. Du; T.J. Carroll; H.J. Wagner; K. Vigen; S.B. Fain; W.F. Block; F.R. Korosec; 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 753 KB

Imaging of the blood vessels below the knee using contrast-enhanced (CE) MRI is challenging due to the need to coordinate image acquisition and arrival of the contrast in the targeted vessels. Time-resolved acquisitions have been successful in consistently capturing images of the arterial phase of t