## Abstract ## Purpose To investigate the utility of nonuniform angular spacing of projections in a three‐dimensional (3D) hybrid undersampled projection reconstruction (PR) acquisition for contrast‐enhanced (CE) time‐resolved carotid imaging. ## Materials and Methods Carotid CE magnetic resonan
Adaptive bilateral breast MRI using projection reconstruction time-resolved imaging of contrast kinetics
✍ Scribed by E. Ramsay; P. Causer; K. Hill; D. Plewes
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 619 KB
- Volume
- 24
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To introduce a bilateral implementation of an adaptive imaging technique in which both dynamic and high resolution breast MR images are acquired simultaneously.
Materials and Methods
Adaptive three‐dimensional bilateral breast imaging in the sagittal plane was achieved by combining two elements: a projection reconstruction time‐resolved imaging of contrast kinetics (PR‐TRICKS) k‐space trajectory and a slab interleaved sequence that imaged alternate breasts every TR. A pilot study was performed to evaluate image quality and contrast uptake behavior, using eight patients with previously identified benign lesions.
Results
Adaptive reconstruction demonstrated breast lesions in all eight women with similar image quality and signal‐to‐noise ratio (SNR) to Cartesian images with comparable imaging parameters. Contrast enhancement curves covering the entire postinjection time period were obtained from the dynamic images and in one case compared to previous enhancement profiles from a conventional Cartesian trajectory.
Conclusion
Bilateral dynamic and high spatial resolution images with high SNR can be achieved in a clinically feasible manner, providing both kinetic and morphologic analysis with a single data set. This may obviate the need for multiple MRI examinations for a thorough breast MRI workup. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Highly‐constrained back‐projection (HYPR) is a technique for the reconstruction of sparse, highly‐undersampled time‐resolved image data. A novel iterative HYPR (I‐HYPR) algorithm is presented and validated in computer simulations. The reconstruction method is then applied to cerebral pe
## Abstract The hybrid projection reconstruction (PR) imaging provides high temporal resolution through an undersampled PR acquisition for the in‐plane dimensions and Cartesian slice encoding for the through‐plane dimension. The undersampling of projection data introduces streak artifact, which may