Imaging of the blood vessels below the knee using contrast-enhanced (CE) MRI is challenging due to the need to coordinate image acquisition and arrival of the contrast in the targeted vessels. Time-resolved acquisitions have been successful in consistently capturing images of the arterial phase of the bolus of contrast agent in the distal extremities. Although time-resolved exams are robust in this respect, higher spatial resolution for the depiction of tight stenoses and the small vessels in the lower leg is desirable. A modification to a high-spatial-resolution T(1)-weighted pulse sequence (projection reconstruction-time resolved imaging of contrast kinetics (PR-TRICKS)) that improves the through-plane spatial resolution by a factor of 2 and maintains a high frame rate is presented. The undersampled PR-TRICKS pulse sequence has been modified to double the spatial resolution in the slice direction by acquiring high-spatial-frequency slice data only after first pass of the bolus of contrast agent. The acquisition reported in the present work (PR-hyperTRICKS) has been used to image healthy volunteers and patients with known vascular disease. The temporal resolution was found to be beneficial in capturing arterial phase images in the presence of asymmetric filling of vessels.


πŸ“œ SIMILAR VOLUMES


Time-resolved undersampled projection re
✍ Jiang Du; Aiming Lu; Walter F. Block; Francis J. Thornton; Thomas M. Grist; Char πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 428 KB

## Abstract The hybrid projection reconstruction (PR) imaging provides high temporal resolution through an undersampled PR acquisition for the in‐plane dimensions and Cartesian slice encoding for the through‐plane dimension. The undersampling of projection data introduces streak artifact, which may

SNR improvement for multiinjection time-
✍ J. Du; T.J. Carroll; W.F. Block; S.B. Fain; F.R. Korosec; T.M. Grist; C.A. Mistr πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 505 KB

## Abstract Peripheral MR angiography (MRA) should ideally provide images over a large field of view with high spatial resolution and adequate temporal resolution to accommodate differences in regional filling times. Image subtraction is usually used to remove background signals. In examination pro