โœฆ Synopsis


There is conflicting evidence regarding the reproducibility of patch testing. Discordant results have been reported in up to 44% of cases. The clinical relevance of these discordant patch tests has not been previously assessed. We studied 383 consecutive patients receiving simultaneous duplicate patch testing on opposite sides of the upper back with 10 allergens from the European standard series. Completely discordant patch tests-a negative test on one side with a positive test on the opposite side-were recorded in 30 (8%) patients. Two patients had discordant tests to two of the allergens; 28 had discordant reactions to one allergen. Completely discordant tests were recorded for nickel in 10 (3%) patients, balsam of Peru in two (0.5%), thiomersal in one (0.3%), cobalt in four (1%), paraphenylenediamine in three (0.8%), fragrance mix in two (0.5%), formaldehyde in four (1%), potassium dichromate in two (0.5%), lanolin in three (0.8%) and Kathon CG in one (0.3%). Of those patients with completely discordant patch tests, the allergen was deemed to be a true positive in 11 (3% of total) cases and of possible relevance in a further three. The allergen was felt to be relevant to the presenting complaint in seven (2% of total) patients.


๐Ÿ“œ SIMILAR VOLUMES


The limitations of the patch test
โœ F. Stummel ๐Ÿ“‚ Article ๐Ÿ“… 1980 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 572 KB
The patch test for elements
โœ Abdur Razzaque ๐Ÿ“‚ Article ๐Ÿ“… 1986 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 484 KB
Accuracy and reproducibility of instrume
โœ Dr. Ph. Edixhoven; Dr. R. Huiskes; R. De Graaf; Th. J. G. Van Rens; T. J. Slooff ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 920 KB

Instrumented devices for knee-drawer tests have become popular in orthopaedics relatively recently. The objective of the present study was to document the effects of several parameters on the accuracy and reproducibility of anterior-posterior (AP) drawer measurements. An instrumented knee-drawer tes

An engineers' defence of the patch test
โœ Bruce Irons; Matti Loikkanen ๐Ÿ“‚ Article ๐Ÿ“… 1983 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 693 KB
Re-visiting the contact patch test
โœ M. A. Crisfield ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 138 KB

The paper uses the contact patch test to assess both linear and quadratic elements in relation to straight and curved contact surfaces. A new contact formulation is proposed which uses a combination of linear and quadratic shape functions. The potential advantages of the new formulation are demonstr