β¦ Synopsis
A partially filling technique for the analysis of DNA markers and polymerase chain reaction (PCR) products by capillary electrophoresis in the presence of electroosmotic flow using polymer solutions is presented. Either after or prior to the sample injection, a plug of salts at high pH was hydrodynamically injected. During the separation, poly(ethylene oxide) (PEO) solution entered the capillary. We have found that the position, length, and composition of the plugs affect the sensitivity, resolution, and speed on the analysis of PhiX-174/HaeIII DNA restriction fragments or a DNA mixture (pBR 322/HaeIII digest, pBR 328/BglI digest and pBR 328/HinfI digest) with different degrees. Through careful evaluation of the impact of anions and cations on the analysis of DNA, we have suggested that the optimal condition is applying a plug consisting of 32 mM NaCl and 0.01 M NaOH at 30 cm height for 60 s after sample injection. In the presence of such a plug, PEO adsorption reduces, and thus the separation is faster, as well as the sensitivity improves. Using this condition, the analysis of a DNA mixture (injected at 30 cm for 360 s) containing ten different PCR products amplified after 17 cycles was complete in 25 min. About a 2000-fold improvement in the sensitivity was achieved when compared to that by a conventional method (10 s injection) without applying a plug.
π SIMILAR VOLUMES
## Abstract We have demonstrated in a systematic manner that the capillary electrophoresis (CE) method of genotyping the human D1S80 locus is an effective replacement for the commonly used gel electrophoresis method. The CE method is fast, with a total run time of less than 22 min per sample. Separ
Immobilization of the restriction enzymes HaeIII and HindIII on porous silica particles via a glutaraldehyde linkage for the micro-digestion of dsDNA with analysis by capillary electrophoresis Solid-phase DNA restriction digest reactors have been developed consisting of silica particles modified wit
## Abstract A capillary electrophoretic method was developed for the determination of the diastereomeric composition of the bradykinin B~2~ antagonist, SBβ238592βDB. The nonionic surfactant Brij 35 was demonstrated to be suitable for the baseline resolution of the three diastereoisomers of SBβ23859