Analysis of the D1S80 locus by capillary electrophoresis
✍ Scribed by Joseph W. Mitchell; David Walsh
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 564 KB
- Volume
- 19
- Category
- Article
- ISSN
- 0173-0835
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
We have demonstrated in a systematic manner that the capillary electrophoresis (CE) method of genotyping the human D1S80 locus is an effective replacement for the commonly used gel electrophoresis method. The CE method is fast, with a total run time of less than 22 min per sample. Separation has been optimized so that resolution for all pairs of alleles from 14 through 41 is greater than 1, providing unambiguous identification. The method utilizes run buffer containing 0.30% hydroxyethyl cellulose as the sieving polymer in a 50 μm internal diameter (ID) column coated with a 0.1 μm DB‐17 film. Laserinduced fluorescence (LIF) with YO‐PRO‐1 intercalating dye is used for detec‐tion. Internal standards of 300 and 1000 bp bracket the DlS80 region in the electropherogram. Two typing procedures were evaluated: matching of the normalized migration times of sample alleles to ladder alleles; and software alignment of sample and ladder electropherograms using the internal standard peaks as references. Using the first procedure, 91.5% of the D1S80 genotypes were unambiguous, while 100% were unambiguous using the second procedure. Seventy‐nine routine samples were analyzed in a side‐by‐side comparison of the CE and slab gel methods, with complete agreement of the results. Twenty‐two samples were selected from a large database previously analyzed by the slab gel method to demonstrate that all alleles from 14 through 41 were typed correctly, including samples containing adjacent alleles. Additionally, 43 samples containing alleles greater than the 41 repeat number were typed correctly.
📜 SIMILAR VOLUMES
## Abstract Recent developments in the characterization of antibiotics are reviewed. Many capillary electrophoretic techniques have been utilized in their analyses, addressing various aspects of quantifying, profiling, and monitoring. Laser‐induced fluorescence detection systems demonstrated their
This article reviews recent developments in the characterization of antibiotics. Many capillary electrophoretic techniques have been utilized in their analyses, addressing various aspects of quantifying, profiling and monitoring. Sensitive electrochemical and laser-induced fluorescence detection sys