𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The determination of caesium and silver in soil and fungal fruiting bodies by electrothermal atomic absorption spectrometry

✍ Scribed by Peter Anderson; Christine M. Davidson; David Littlejohn; Allan M. Ure; Charles A. Shand; Martin V. Cheshire


Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
733 KB
Volume
327
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


Methods have been developed for the determination of caesium and silver in soil and fungal samples by microwave-assisted aqua regia digestion, followed by electrothermal atomic absorption spectrometry. The procedure was found to be repeatable (for soil, RSD < 5%, n = 3, at caesium and silver concentrations of 1.8 and 0.6 mg g-' , respectively, and for fungi, RSD < 7%, n = 5, at caesium and silver levels of 20 and 1 mg g-', respectively) and reasonably efficient. Silver was recovered quantitatively from reference soils, but only about 80-85% of the caesium present could be extracted. Poorer caesium recoveries (< 70%) were obtained if, as part of the sample preparation procedure, solutions were taken to dryness in glass beakers prior to analysis. The detection limits were 0.02 mg Ag and 0.09 mg Cs per gram of dry soil, which are adequate for the determination of the analytes at typical environmental levels. The methods were applied in the analysis of three types of soil, a peaty podzol, a clay loam and a sandy loam and no significant matrix interferences were observed except in the determination of caesium in the sandy loam. For caesium, non-linear response curves, thought to be due to ionisation interference, were encountered using one atomic absorption spectrometer, but were not observed with the other instrument.


πŸ“œ SIMILAR VOLUMES


Slurry sampling for the determination of
✍ I LΓ³pez-GarcΓ­a; M SΓ‘nchez-Merlos; M HernΓ‘ndez-CΓ³rdoba πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 626 KB

To determine the lead and cadmium content of soils and sediments, the samples are suspended in water containing 5% (v/v) concentrated hydrofluoric acid before injected into the electrothermal atomizer. For thallium determination a 30% hydrofluoric acid solution is used as the suspension medium. In a

Atomization Characteristic of Chromium o
✍ Kiyohisa Ohta; Hiroya Uegomori; Syn-ichi Itoh; Takayuki Mizuno πŸ“‚ Article πŸ“… 1997 πŸ› Elsevier Science 🌐 English βš– 110 KB

Atomization characteristics of chromium have been studied by electrothermal atomic absorption spectrometry with a molybdenum tube atomizer. The appearance temperature (T app ) of chromium nitrate was 1300ЊC. The T app was independent of the heating rate of atomizer, but the temperature at the peak o