𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Slurry sampling for the determination of lead, cadmium and thallium in soils and sediments by electrothermal atomic absorption spectrometry with fast-heating programs

✍ Scribed by I López-García; M Sánchez-Merlos; M Hernández-Córdoba


Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
626 KB
Volume
328
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


To determine the lead and cadmium content of soils and sediments, the samples are suspended in water containing 5% (v/v) concentrated hydrofluoric acid before injected into the electrothermal atomizer. For thallium determination a 30% hydrofluoric acid solution is used as the suspension medium. In accordance with fast-heating methodology, the conventional ashing step is replaced by a modified drying stage performed by programming the instrument to 400°C. No modifier other than hydrofluoric acid is required. Calibration is performed directly using aqueous standards for cadmium and lead determination. For thallium the standard additions method is recommended. The results obtained for five certified reference materials show the reliability of the procedures.


📜 SIMILAR VOLUMES


Slurry Sampling Techniques for the Deter
✍ Mohammad Arifur Rahman; Satoshi Kaneco; Tohru Suzuki; Hideyuki Katsumata; Kiyohi 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 81 KB 👁 2 views

Ultrasonic slurry sampling electrothermal atomic absorption spectrometry with a metal tube atomizer has been applied to the determination of lead in Bangladeshi fish samples. The slurry sampling conditions, such as slurry stabilizing agent, slurry concentration, pyrolysis temperature for the slurrie

Slurry-electrothermal atomic absorption
✍ Ignacio López García; Jesus Arroyo Cortéz; Manuel Hernández Córdoba 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 709 KB

## AhStrpCt The determination of cadmium, zinc and manganese in diatomaceous earth, as well as in other materials with high silica content, is carried out by first suspending the ground samples in dilute hydrofluoric acid. Following this, aliquots of the slurries are directly injected into the ele

Selective flow injection sorbent extract
✍ Renli Ma; Willy Van Mol; Freddy Adams 📂 Article 📅 1994 🏛 Elsevier Science 🌐 English ⚖ 964 KB

A flow injection sorbent extraction system was developed for determination of trace and ultratrace cadmium, copper and lead in biological and environmental standard reference materials by graphite furnace atomic absorption spectrometty (GFAAS). Using ammonium diethyldithiophosphate (DDPA) as complex

Robotic sample pretreatment coupled with
✍ Alfredo Velasco-Arjona; María Dolores Luque de Castro; Elissaveta Ivanova; Fredd 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 172 KB 👁 2 views

An automated robotic method for sample pretreatment was developed for copper determination in environmental and biological materials at the low microgram per gram level. The robotic station performing the preliminary operations as weighing of sample and acid digestion was coupled with the flowinject