Atomization Characteristic of Chromium on a Molybdenum Tube Atomizer by Electrothermal Atomic Absorption Spectrometry and Determination of Chromium in Biological Materials

โœ Scribed by Kiyohisa Ohta; Hiroya Uegomori; Syn-ichi Itoh; Takayuki Mizuno


Publisher
Elsevier Science
Year
1997
Tongue
English
Weight
110 KB
Volume
56
Category
Article
ISSN
0026-265X

No coin nor oath required. For personal study only.

โœฆ Synopsis


Atomization characteristics of chromium have been studied by electrothermal atomic absorption spectrometry with a molybdenum tube atomizer. The appearance temperature (T app ) of chromium nitrate was 1300ะŠC. The T app was independent of the heating rate of atomizer, but the temperature at the peak of the Cr AA signal increased with the heating rate. A sensitive absorption chromium signal was obtained in pure argon purge gas. The chromium signal decreased as the ratio of hydrogen in the purge gas increased. The optimal gas flow rate was Ar 480 ml min 01 / H 2 20 ml min 01 because of the avoidance of oxidation of the atomizer. The absolute characteristic mass (the mass of element giving 0.0044 abs.) of chromium by the atomizer was 0.35 pg and the detection limit was 23 pg ml 01 (3S/N). The interferences caused by large amounts of interferents were evaluated. The addition of thiourea served to eliminate the severe interferences. The accuracies of the recommended method were considered almost satisfactory for the determination of chromium in biological materials, compared with the certified values of NIST materials. The recovery of spiked chromium in biological materials was in the range from 93.5 to 102%.


๐Ÿ“œ SIMILAR VOLUMES


Electrothermal Atomic Absorption Spectro
โœ K. Ohta; K. Mizutani; S. Itoh; T. Mizuno ๐Ÿ“‚ Article ๐Ÿ“… 1993 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 388 KB

Electrothermal atomic absorption spectrometry (ETA-AAS) of potassium in biological materials with a molybdenum tube atomizer has been investigated. The atomization characteristics of potassium on the atomizer are demonstrated. The optimal gas flow rate was \(400 \mathrm{ml} \mathrm{min}^{-1} \mathrm

Slurry Sampling Techniques for the Deter
โœ Mohammad Arifur Rahman; Satoshi Kaneco; Tohru Suzuki; Hideyuki Katsumata; Kiyohi ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 81 KB ๐Ÿ‘ 2 views

Ultrasonic slurry sampling electrothermal atomic absorption spectrometry with a metal tube atomizer has been applied to the determination of lead in Bangladeshi fish samples. The slurry sampling conditions, such as slurry stabilizing agent, slurry concentration, pyrolysis temperature for the slurrie

Preconcentration of chromium, copper and
โœ F. Baffi; A.M. Cardinale; R. Bruzzone ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 491 KB

A systematic study of the use in "batch equilibration" of pretreated solid Chelex-100 and Lewatit TP 207 (H + form) for the preconcentration of Cr(III), Cu(II) and Mn(II) dissolved in sea water is presented. The preparation of the resin and the suggested procedure are useful because sea water can be