𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The biocompatibility of polypyrrolidone in test implantation

✍ Scribed by ?princl, L. ;Ku?kov�, M. ;Roda, J. ;Kr�l�?ek, J.


Publisher
John Wiley and Sons
Year
1982
Tongue
English
Weight
643 KB
Volume
16
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The biological compatibility of polypyrrolidone was investigated using subcutaneous implantation in rats. Acute (10 days) and chronic (360 days after implantation) tissue reaction was characterized numerically and compared with poly(2‐hydroxyethyl methacrylate), used in the Drug Control Research Institute in Prague as a standard in the evaluation of polymers, for which good tolerance in the clinical practice has been demonstrated. Surface changes in the polymer were evaluated by using a scanning electron microscope.


📜 SIMILAR VOLUMES


Biocompatibility testing of polymers:In
✍ Gourlay, Stuart J. ;Rice, Robert M. ;Hegyeli, Andrew F. ;Wade, Clarence W. R. ;D 📂 Article 📅 1978 🏛 John Wiley and Sons 🌐 English ⚖ 612 KB

## Abstract An __in vivo__ method is described for screening polymeric materials for biocompatibility. The test is based on grading acute and subacute tissue reactions at 7 and 28 days, respectively, following implantation in rats. The method is reproducible and reliable. It is designed to provide

Biocompatibility testing of NiTi screws
✍ Berger-Gorbet, M. ;Broxup, B. ;Rivard, C. ;Yahia, L'H. 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 692 KB

NiTi is one of the most innovative concepts to have appeared in the field of metallic biomaterials in recent years but its biocompatibility remains controversial. We evaluated the biocompatibility of Nitinol screws using immunohistochemistry to observe the distribution of bone proteins during bone r

In Vivo Biocompatibility of Three Potent
✍ Sylvie Defrère; Mélanie Mestagdt; Raphaël Riva; Fabrice Krier; Anne Van Langendo 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 554 KB

## Abstract The intraperitoneal biocompatibility of PDMS, polyHEMA and pEVA was investigated in rats, rabbits and rhesus monkeys. No inflammation was evidenced by hematological analyses and measurement of inflammatory markers throughout the experiment and by post‐mortem examination of the pelvic ca

In vivo biocompatibility testing of peek
✍ Rivard, Charles-H ;Rhalmi, Souad ;Coillard, Christine 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 735 KB

## Abstract We are developing a new spinal implant system (SIS) without fusion (bone graft). This SIS is made from two materials, metal and polyetheretherketone (PEEK) polymer. The Food and Drug Administration recommended testing __in vivo,__ in an animal model, whether the PEEK polymer could be us