Study of hydrogen in hydrogenated Pd/semiconductor device by ERDA
β Scribed by PC Srivastava; U.P. Singh; S.P. Pandey; D.K. Avasthi
- Publisher
- Elsevier Science
- Year
- 1996
- Tongue
- English
- Weight
- 322 KB
- Volume
- 47
- Category
- Article
- ISSN
- 0042-207X
No coin nor oath required. For personal study only.
β¦ Synopsis
The content of hydrogen in Pd/n-Si, Pd/p-Si, and Pd/p-GaAs devices have been measured, both in the semiconducting substrates and the palladium thin film deposited on p-type Si, n-type Si and p-type GaAs, by ERDA (Elastic Recoil Detection Analysis) using 55 Mev Si ions. The samples were hydrogenated by keeping them in the atmosphere of molecular hydrogen at a pressure of 1 atm at room temperature. It is found that there is a fairly large amount of hydrogen in the semiconductor substrates and the palladium overlayers. It seems that the hydrogen absorbed by the palladium overlayers diffuses to the semiconducting substrates through the Pd/Semiconductor interface. It is found that the p-type semiconducting substrates accommodate more hydrogen than n-type semiconducting substrates in such hydrogenated samples.
π SIMILAR VOLUMES
A special cell was constructed for studying the interaction of hydrogen with materials. It enabled exposure of samples to a neutral hydrogen atmosphere and simultaneous concentration depth profiling of H and D. The concentration of individual hydrogen isotopes was measured by elastic recoil detectio