Structural Analysis of Lignin by Resonance Raman Spectroscopy
✍ Scribed by Søren Barsberg; Pavel Matousek; Mike Towrie
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 225 KB
- Volume
- 5
- Category
- Article
- ISSN
- 1616-5187
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Summary: Resonance Raman (RR) spectroscopy, combined with Kerr gated fluorescence rejection in the time domain, has recently elucidated lignin structure with unique sensitivity and selectivity. This promises structural studies of fluorescent natural macromolecules, such as lignin, which were previously not possible. Such studies rely on an improved understanding of the RR spectral behavior of lignin, which is today scarcely understood. We explain for the first time this behavior by a semi‐empirical theory, and observe its pertinent features for lignin in vascular plants. We have used well‐defined oxidative treatments as means of probing lignin structural elements, and show that RR sensitivity and selectivity depend crucially on excitation wavelength. Through the theory we relate these results to basic structural aspects of lignin. Spectra obtained by blue light laser excitation (400 nm) are dominated by low redox potential syringyl lignin groups, whereas lower photon energy (500 nm) decreases the selectivity markedly. RR bands depend on molecular structure but also on molecular environment. Thus charge transfer donor‐acceptor interactions within lignin reduce the intensity of bands associated with electron rich moieties. New possibilities for basic and selective structural information on fluorescent natural materials, such as lignin, have thus appeared.
Raman scattering in relation to typical electronic state energies of lignin structures.
magnified imageRaman scattering in relation to typical electronic state energies of lignin structures.
📜 SIMILAR VOLUMES
FT-Raman spectroscopy is used for the rapid measurement of wood pulp lignin. A total of 23 western softwood pulp samples with known kappa numbers (10 -38) are used. Each sample is divided into three portions and scanned separately. The integrated area of the lignin band at approximately 1600 cm 01 i
## Abstract ## Background and Objective We examine the use of Raman spectroscopy to analyze components in human urine. ## Study Design/Materials and Methods Targeted urine components include urea, uric acid, and creatinine. ## Results Urea concentration in urine is sufficiently high that norma