Stent recoil: Comparison of the Wiktor-GX coil and the Palmaz-Schatz tubular coronary stent

✍ Scribed by White, Christopher J.


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
26 KB
Volume
41
Category
Article
ISSN
0098-6569

No coin nor oath required. For personal study only.

✦ Synopsis


Wiktor-GX coil stents and Palmaz-Schatz 154A tubular stents were implanted in a consecutive series of 40 patients and 45 arteries undergoing successful primary stent placement in de novo lesions treated with single stents in order to compare the acute recoil of a coil stent to a tubular stent in native coronary arteries. Acute stent recoil was determined by measuring the difference between the maximum inflated diameter of the stent deployment balloon and the minimum lumen diameter after stent deployment. There was no difference between the two groups for reference vessel diameter, nominal balloon diameter, maximum inflated balloon diameter, maximum inflation pressure, or poststent vessel minimum lumen diameter. Acute recoil averaged 0.15 +/- 0.2 mm for the Wiktor-GX and 0.13 +/- 0.1 for the Palmaz-Schatz (P = 0.58). In this series of patients, there was no significant difference between the acute recoil of the coil stent compared to the tubular stent.


πŸ“œ SIMILAR VOLUMES


Randomised comparison of micro stent I w
✍ Menafoglio, Andrea ;Eeckhout, Eric ;Debbas, Nadia ;Faivre, RenΓ© ;Petiteau, Pierr πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 38 KB πŸ‘ 2 views

This randomised trial compared the Micro Stent I and the Palmaz-Schatz stent for the elective treatment of short (F8 mm long), new-onset coronary stenoses. The primary endpoints were restenosis rate and minimal luminal diameter at 6 mo angiographic follow-up. The secondary endpoints were angiographi

Bent stents: A method to facilitate deli
✍ Lee, Benjamin I. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 253 KB πŸ‘ 2 views

The Palmaz-Schatz stent delivery system (PS 153) and ''bare'' PS 204 stents are relatively high-profile, rigid devices that can be difficult to deliver to lesions beyond tortuous, irregular, or rigid proximal segments. Described herein is a method of mounting and shaping a Palmaz-Schatz stent on a l

Use of coronary Palmaz-Schatz stent in t
✍ Feldman, Robert L. ;Rubin, Jay J. ;Kuykendall, R. Craig πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 366 KB πŸ‘ 2 views

A case of chronic vertebrobasilar insufficiency due to severe stenoses at the origins of both vertebral arteries was treated with percutaneous transluminal angioplasty and coronary Palmaz-Schatz stents. Use of stents led to a better angiographic result than angloplasty alone. The patient Is improved

Thrombotic occlusion of the coronary art
✍ Shiojima, Ichiro ;Ikari, Yuji ;Abe, Jun-Ichi ;Ishizaka, Nobukazu ;Maemura, Koji πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 254 KB πŸ‘ 2 views

We describe a case of coronary stenting in which accidental detachment of the Palmaz-Schatr stent induced thrombotic occlusion of the coronary artery. This case suggests that careful consideration of the risk involving coronary occlusion is mandatory on d e ciding the therapeutic strategy of the cas