Stent recoil: Comparison of the Wiktor-GX coil and the Palmaz-Schatz tubular coronary stent
β Scribed by White, Christopher J.
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 26 KB
- Volume
- 41
- Category
- Article
- ISSN
- 0098-6569
No coin nor oath required. For personal study only.
β¦ Synopsis
Wiktor-GX coil stents and Palmaz-Schatz 154A tubular stents were implanted in a consecutive series of 40 patients and 45 arteries undergoing successful primary stent placement in de novo lesions treated with single stents in order to compare the acute recoil of a coil stent to a tubular stent in native coronary arteries. Acute stent recoil was determined by measuring the difference between the maximum inflated diameter of the stent deployment balloon and the minimum lumen diameter after stent deployment. There was no difference between the two groups for reference vessel diameter, nominal balloon diameter, maximum inflated balloon diameter, maximum inflation pressure, or poststent vessel minimum lumen diameter. Acute recoil averaged 0.15 +/- 0.2 mm for the Wiktor-GX and 0.13 +/- 0.1 for the Palmaz-Schatz (P = 0.58). In this series of patients, there was no significant difference between the acute recoil of the coil stent compared to the tubular stent.
π SIMILAR VOLUMES
This randomised trial compared the Micro Stent I and the Palmaz-Schatz stent for the elective treatment of short (F8 mm long), new-onset coronary stenoses. The primary endpoints were restenosis rate and minimal luminal diameter at 6 mo angiographic follow-up. The secondary endpoints were angiographi
The Palmaz-Schatz stent delivery system (PS 153) and ''bare'' PS 204 stents are relatively high-profile, rigid devices that can be difficult to deliver to lesions beyond tortuous, irregular, or rigid proximal segments. Described herein is a method of mounting and shaping a Palmaz-Schatz stent on a l
A case of chronic vertebrobasilar insufficiency due to severe stenoses at the origins of both vertebral arteries was treated with percutaneous transluminal angioplasty and coronary Palmaz-Schatz stents. Use of stents led to a better angiographic result than angloplasty alone. The patient Is improved
We describe a case of coronary stenting in which accidental detachment of the Palmaz-Schatr stent induced thrombotic occlusion of the coronary artery. This case suggests that careful consideration of the risk involving coronary occlusion is mandatory on d e ciding the therapeutic strategy of the cas