𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Use of coronary Palmaz-Schatz stent in the percutaneous treatment of vertebral artery stenoses

✍ Scribed by Feldman, Robert L. ;Rubin, Jay J. ;Kuykendall, R. Craig


Publisher
John Wiley and Sons
Year
1996
Tongue
English
Weight
366 KB
Volume
38
Category
Article
ISSN
0098-6569

No coin nor oath required. For personal study only.

✦ Synopsis


A case of chronic vertebrobasilar insufficiency due to severe stenoses at the origins of both vertebral arteries was treated with percutaneous transluminal angioplasty and coronary Palmaz-Schatz stents. Use of stents led to a better angiographic result than angloplasty alone. The patient Is improved 8 mo later. Q iggs wiley-UU, inc.


πŸ“œ SIMILAR VOLUMES


Use of coronary Palmaz-Schatz stent in t
✍ Feldman, Robert L. ;Trigg, Lance ;Gaudler, Jose ;Galat, John πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 453 KB πŸ‘ 1 views

A 69yrsld man had chronic transient Ischemia attacks due to severe stenosis of the lntracranial portion of the right carotid artery. After failure of both antlpiateiet and anticoagulant therapy, treatment was successful wlth percutaneous translumlnal angioplasty and a coronary Paimaz-Schatz stent. U

Randomised comparison of micro stent I w
✍ Menafoglio, Andrea ;Eeckhout, Eric ;Debbas, Nadia ;Faivre, RenΓ© ;Petiteau, Pierr πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 38 KB πŸ‘ 1 views

This randomised trial compared the Micro Stent I and the Palmaz-Schatz stent for the elective treatment of short (F8 mm long), new-onset coronary stenoses. The primary endpoints were restenosis rate and minimal luminal diameter at 6 mo angiographic follow-up. The secondary endpoints were angiographi

Thrombotic occlusion of the coronary art
✍ Shiojima, Ichiro ;Ikari, Yuji ;Abe, Jun-Ichi ;Ishizaka, Nobukazu ;Maemura, Koji πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 254 KB πŸ‘ 1 views

We describe a case of coronary stenting in which accidental detachment of the Palmaz-Schatr stent induced thrombotic occlusion of the coronary artery. This case suggests that careful consideration of the risk involving coronary occlusion is mandatory on d e ciding the therapeutic strategy of the cas

Bent stents: A method to facilitate deli
✍ Lee, Benjamin I. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 253 KB πŸ‘ 2 views

The Palmaz-Schatz stent delivery system (PS 153) and ''bare'' PS 204 stents are relatively high-profile, rigid devices that can be difficult to deliver to lesions beyond tortuous, irregular, or rigid proximal segments. Described herein is a method of mounting and shaping a Palmaz-Schatz stent on a l

Use of coronary artery stents in the tre
✍ Mencken, G. Scott ;Wholey, Mark H. ;Eles, Gustav R. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 174 KB πŸ‘ 1 views

The management of high-grade stenosis involving the petrosal segment of the internal carotid artery has been limited to angioplasty alone in the past. However, if angioplasty fails or has less than optimum results, then endovascular stent placement should be considered. We present the first two know