๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Statistical evaluation of the direct linear plot method for estimation of enzyme kinetic parameters

โœ Scribed by R.C. Kohberger


Publisher
Elsevier Science
Year
1980
Tongue
English
Weight
403 KB
Volume
101
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

โœฆ Synopsis


The efficiencies of estimates obtained from the direct linear plot (A. Cornish-Bowden and R. Eisenthal, 1978, Biochem. Biophys. Acta, 523, 268) are shown to be dependent on the spacing of substrate concentrations. When substrate values are harmonically spaced, the direct linear plot should not be used. The nonparametric confidence limits based on the direct linear plot are accurate in their confidence coefficient, but their efficiencies are shown to be dependent on substrate spacing. Harmonic spacing is, in general, a more efficient experimental design for estimating K, than arithmetic spacing when the appropriate estimation methods are used. if assumptions about the error structure cannot be made, the best procedure for estimating K, is to have harmonic spacing of substrate values and use weighted least squares for estimation. The most accurate and precise estimation of enzyme kinetic parameters requires knowledge of the error structure and utilization of the appropriate nonlinear regression.


๐Ÿ“œ SIMILAR VOLUMES


Direct linear plotting method for estima
โœ Jeffrey R. Koup ๐Ÿ“‚ Article ๐Ÿ“… 1981 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 223 KB

Recently, a method was described (1) for estimating the parameters of a single-compartment linear pharmacokinetic model following intravenous bolus dose administration. This method is based on the following relationship: \* APPLE I1 plus, DOS 3.2.1.

A Simple Fluorimetric Method for the Est
โœ V. Leskovac; S. Trivic; M. Pantelic ๐Ÿ“‚ Article ๐Ÿ“… 1993 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 224 KB

The theory and practice of a simple fluorimetric method for the estimation of ligand binding parameters in ligand-enzyme complexes is described. In this method, the concentration of a ligand-binding enzyme and the dissociation constant of a ligand-enzyme complex were estimated solely from the total

A FREQUENCY DOMAIN METHOD FOR ESTIMATING
โœ D.E. ADAMS; R.J. ALLEMANG ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 250 KB

A unifying perspective of non-linear structural dynamic systems as linear in the open loop with non-linear feedback in the closed loop has recently been revisited by the authors. The authors have previously used feedback to derive a new formulation of frequency response function matrices of non-line