𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Splitless injection and the solvent effect

✍ Scribed by Grob, K. ;Grob, K.


Book ID
102892755
Publisher
John Wiley and Sons
Year
1978
Tongue
English
Weight
700 KB
Volume
1
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Splitless injection is based on the solvent effect as a mechanism condensing large vapour clouds down to infinitely shortened bands. The effect is controlled by the parameters column temperature, volatility and amount of solvent, and rate of injection. By properly selecting the variables the effect can easily be optimized for any combination of sample and column. It is the purpose of this paper to provide the mechanistic understanding as required for this optimization, as well as some rules for the experimental realization. Potentialities and limitations of splitless injection are discussed, and the role of the solvent effect in on‐column injection is emphasized.


πŸ“œ SIMILAR VOLUMES


Concurrent solvent recondensation large
✍ Paolo Magni; Thomas Porzano πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 319 KB

## Abstract Concurrent Solvent Recondensation Large Sample Volume (CRS‐LV) splitless injection overcomes the limitation of the maximum sample volume to 1–2 ΞΌL valid for classical splitless injection. It is based on control of the evaporation rate in the vaporizing chamber, utilization of a strong p

Splitless injection-development and stat
✍ Grob, K. ;LΓ€ubli, Th. ;BrechbΓΌhler, B. πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 771 KB

Kurt Grob introduced splitless injection in 1969. He elaborated most of the working guidelines including the techniques required for reconcentrating the broad initial bands, i.e. the solvent effects and cold trapping. He also designed avaporizing injector suited for splitless injection. Nevertheless

Improving splitless injection with elect
✍ Wylie, Philip L. ;Phillips, Richard J. ;Klein, Kenneth J. ;Thompson, Michael Q. πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 672 KB

## Abstract An experimental injection port has been designed for split or splitless sample introduction in capillary gas chromatography; the inlet uses electronic pressure control, in order that the column head pressure may be set from the GC keyboard, and the inlet may be used in the constant flow

Splitless injection in capillary supercr
✍ Buskhe, A. Farbrot ;Berg, B. E. ;Gyllenhaal, O. ;Greibrokk, T. πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 384 KB πŸ‘ 2 views

A splitless injection technique, allowing 0.5 pI injectionson 50 pm i.d. columns, has been developed.