Some factors that influence the steady state in steady-state free precession
✍ Scribed by Samuel Patz
- Publisher
- Elsevier Science
- Year
- 1988
- Tongue
- English
- Weight
- 986 KB
- Volume
- 6
- Category
- Article
- ISSN
- 0730-725X
No coin nor oath required. For personal study only.
✦ Synopsis
Steady-state free precession (SSFP) and particularly the spatially periodic magnetization response with wavelength A that results in the presence of an applied gradient is discussed. The maximum SSFP magnetization does oot always occur at the Larmor frequency hut rather depends on both the phase cycling of the rf pulses and on the rf tip angle. The slow flow sensitivity of SSFP also depends on X. Experimental data of the flow sensitivity is shown to be parameterized by a dimensionless dephasing parameter d defined as the ratio of the distance traveled by a spin in one cycle of the SSFP sequence as compared to A. An example of the creation of a moving reference frame with the SSFP sequence is given. The modulation in image intensity that results when the gradients are nearly but not exactly compensated and X becomes large (i.e., tens of pixels long) is demonstrated. The pixel length must be an integral number of X's in order to have a uniform image intensity from a uniform phantom.
📜 SIMILAR VOLUMES
## Abstract Steady‐state free precession (SSFP) cardiac cine images are frequently corrupted by dark flow artifacts, which can usually be eliminated by reshimming and retuning the scanner. A theoretical explanation for these artifacts is provided in terms of spins moving through an off‐resonant poi
## Abstract An analysis of the effect of flow on 2D fully balanced steady state free precession (SSFP) imaging is presented. Transient and steady‐state SSFP signal intensities in the presence of steady and pulsatile flow were simulated using a matrix formalism based on the Bloch equations. Various
## Abstract Linear magnetic field gradients spatially encode the image information in MRI. Concomitant gradients are undesired magnetic fields that accompany the desired gradients and occur as an unavoidable consequence of Maxwell's equations. These concomitant gradients result in undesired phase a
## Abstract Steady‐state free precession (SSFP) imaging with an added field gradient pulse is strongly sensitive to self‐diffusion and other motions of water. In an earlier theoretical analysis of diffusion attenuation due to a single gradient pulse Wu and Buxton (__J. Magn. Reson.__ 90, 243, 1990)
## Abstract Recently, it has been demonstrated that oxygen‐weighted images of whole blood can be obtained with steady‐state methods. In this article, based on computational and experimental models, we investigate the potential for employing this technique to monitor oxygen changes in microcirculati