𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Sodium MRI of the human kidney at 3 Tesla

✍ Scribed by Nimrod Maril; Yael Rosen; Glenn H. Reynolds; Alex Ivanishev; Long Ngo; Robert E. Lenkinski


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
337 KB
Volume
56
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The sodium concentration gradient in the kidney (from the cortex to the medulla) serves to regulate fluid homeostasis and is tightly coupled to renal function. It was previously shown that renal function and pathophysiology can be characterized in rat kidneys by measuring the sodium gradient with ^23^Na MRI. This study demonstrates for the first time the ability of ^23^Na MRI to map the distribution of sodium in the human kidney and to quantify the corticomedullary sodium gradient. The study was performed on a 3T Signa LX scanner (GE) using an in‐house‐built quadrature surface coil. ^23^Na images of volunteers were acquired using a 3D coronal gradient‐echo sequence at a spatial resolution of 0.3 × 0.3 × 1.5 cm^3^ in a 25‐min scan time. The signal intensity (relative to the noise) increased linearly from the cortex to each of the medullae with a mean slope of 1.6 ± 0.2 in relative arbitrary units per mm (Rel.u./mm, N = 6) and then decreased, as expected, toward the renal pelvis. Water deprivation (12 hr) induced a significant increase of 25% (P < 0.05) in this gradient. Based on these results, we suggest that sodium MRI can serve as a valuable noninvasive method for functional imaging of the human kidney. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Fast T2*-weighted MRI of the prostate at
✍ Rulon L. Hardman; Fadi El-Merhi; Adam J. Jung; Steve Ware; Ian M. Thompson; Harr 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 314 KB 👁 1 views

## Abstract ## Purpose: To describe a rapid T2\*‐weighted (T2\*W), three‐dimensional (3D) echo planar imaging (EPI) sequence and its application in mapping local magnetic susceptibility variations in 3 Tesla (T) prostate MRI. To compare the sensitivity of T2\*W EPI with routinely used T1‐weighted

Diffusion tensor MRI of the human kidney
✍ Mario Ries; Richard A. Jones; Fabrice Basseau; Chrit T.W. Moonen; Nicolas Grenie 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 409 KB
Diffusion tensor MRI of the human kidney
✍ Mario Ries; Richard A. Jones; Fabrice Basseau; Chrit T.W. Moonen; Nicolas Grenie 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 409 KB

## Abstract This study characterizes the diffusion anisotropy of the human kidney using a diffusion‐weighted, single‐shot echo planar imaging (EPI) sequence in order to access the full apparent diffusion tensor (ADT) within one breathhold. The fractional anisotropy (FA) of the cortex and the medull