𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Fast T2*-weighted MRI of the prostate at 3 tesla

✍ Scribed by Rulon L. Hardman; Fadi El-Merhi; Adam J. Jung; Steve Ware; Ian M. Thompson; Harry T. Friel; Qi Peng


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
314 KB
Volume
33
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose:

To describe a rapid T2*‐weighted (T2*W), three‐dimensional (3D) echo planar imaging (EPI) sequence and its application in mapping local magnetic susceptibility variations in 3 Tesla (T) prostate MRI. To compare the sensitivity of T2*W EPI with routinely used T1‐weighted turbo‐spin echo sequence (T1W TSE) in detecting hemorrhage and the implications on sequences sensitive to field inhomogeneities such as MR spectroscopy (MRS).

Materials and Methods:

B~0~ susceptibility weighted mapping was performed using a 3D EPI sequence featuring a 2D spatial excitation pulse with gradients of spiral k‐space trajectory. A series of 11 subjects were imaged using 3T MRI and combination endorectal (ER) and six‐channel phased array cardiac coils. T1W TSE and T2*W EPI sequences were analyzed quantitatively for hemorrhage contrast. Point resolved spectroscopy (PRESS MRS) was performed and data quality was analyzed.

Results:

Two types of susceptibility variation were identified: hemorrhagic and nonhemorrhagic T2*W‐positive areas. Post‐biopsy hemorrhage lesions showed on average five times greater contrast on the T2*W images than T1W TSE images. Six nonhemorrhage regions of severe susceptibility artifact were apparent on the T2*W images that were not seen on standard T1W or T2W images. All nonhemorrhagic susceptibility artifact regions demonstrated compromised spectral quality on 3D MRS.

Conclusion:

The fast T2*W EPI sequence identifies hemorrhagic and nonhemorrhagic areas of susceptibility variation that may be helpful in prostate MRI planning at 3.0T. J. Magn. Reson. Imaging 2011;33:902–907. © 2011 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


T2-weighted 3D fMRI using S2-SSFP at 7 t
✍ Markus Barth; Heiko Meyer; Stephan A. R. Kannengiesser; Jonathan R. Polimeni; La 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 334 KB

In this study, the sensitivity of the S 2 -steady-state free precession (SSFP) signal for functional MRI at 7 T was investigated. In order to achieve the necessary temporal resolution, a three-dimensional acquisition scheme with acceleration along two spatial axes was employed. Activation maps based

MRI of the neck at 3 Tesla using the per
✍ Yoshimitsu Ohgiya; Jumpei Suyama; Noritaka Seino; Shu Takaya; Masaaki Kawahara; 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 278 KB 👁 2 views

## Abstract ## Purpose: To evaluate motion artifacts, tissue contrasts, and lesion detectability in the neck with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) technique. ## Materials and Methods: A total of 46 patients referred for MRI of t

Prostate cancer detection with 3 T MRI:
✍ Kazuhiro Kitajima; Yasushi Kaji; Yoshitatsu Fukabori; Ken-ichiro Yoshida; Narufu 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 198 KB 👁 1 views

## Abstract ## Purpose: To evaluate the diagnostic ability of diffusion‐weighted imaging (DWI) and dynamic contrast‐enhanced imaging (DCEI) in combination with T2‐weighted imaging (T2WI) for the detection of prostate cancer using 3 T magnetic resonance imaging (MRI) with a phased‐array body coil.

Motion correction in diffusion-weighted
✍ Lori R. Arlinghaus; E. Brian Welch; A. Bapsi Chakravarthy; Lei Xu; Jaime S. Farl 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 319 KB 👁 1 views

## Abstract ## Purpose: To provide a quantitative assessment of motion and distortion correction of diffusion‐weighted images (DWIs) of the breast and to evaluate the effects of registration on the mean apparent diffusion coefficient (mADC). ## Materials and Methods: Eight datasets from four pat