𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Diffusion tensor MRI of the human kidney

✍ Scribed by Mario Ries; Richard A. Jones; Fabrice Basseau; Chrit T.W. Moonen; Nicolas Grenier


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
409 KB
Volume
14
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

This study characterizes the diffusion anisotropy of the human kidney using a diffusion‐weighted, single‐shot echo planar imaging (EPI) sequence in order to access the full apparent diffusion tensor (ADT) within one breathhold. The fractional anisotropy (FA) of the cortex and the medulla were found to be 0.22 ± 0.12 and 0.39 ± 0.11, respectively (N = 10), which emphasizes the need for rotationally invariant diffusion measurements for clinical applications. Additional limitations for clinical diffusion imaging on the kidney are the strong susceptibility variations within the abdomen that restrict the use of imaging techniques employing long echo trains, and the severe motion sensitivity that limits the available imaging time to one breath‐hold. To overcome these problems an isotropic, diffusion‐weighted, segmented EPI protocol that facilitates the acquisition of high‐resolution diffusion‐weighted images within a single breath‐hold was implemented. Using this method, the apparent diffusion coefficient (ADC) of the cortex and medulla were found to be 2.89 ± 0.28 · 10^−9^ m^2^/s and 2.18 ± 0.36 · 10^−9^ m^2^/s (N = 10). J. Magn. Reson. Imaging 2001;14:42–49. © 2001 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Diffusion tensor MRI of the human kidney
✍ Mario Ries; Richard A. Jones; Fabrice Basseau; Chrit T.W. Moonen; Nicolas Grenie 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 409 KB
Diffusion tensor MRI of the spinal cord
✍ Mario Ries; Richard A. Jones; Vincent Dousset; Chrit T.W. Moonen 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 616 KB

Apparent diffusion tensor (ADT) measurements on the spinal cord using a pulsed-field-gradient (PFG) multi-shot echo-planar imaging (EPI) sequence are presented. In a study of 10 healthy volunteers, the obtained rotationally invariant anisotropy information is compared to the results obtained by the

Application of diffusion tensor MRI to n
✍ Andrew Simmons; Derek K. Jones; Mark A. Horsfield; Steven C. R. Williams 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 553 KB

We consider the application of segmentation based on cluster classification techniques to a series of images derived from the diffusion tensor. The extension of a sophisticated cluster simulation tool used for optimizing data acquisition for such segmentation methods to diffusion-based images is des

Diffusion tensor imaging of the developi
✍ Rakesh K. Gupta; Khader M. Hasan; Richa Trivedi; Mandakini Pradhan; Vinita Das; 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 261 KB

## Abstract Diffusion tensor imaging (DTI) was performed on 15 fresh spontaneously or therapeutically aborted normal fetuses and five term infants at different gestational ages. Regional cortical fractional anisotropy (FA) values were observed to increase with gestational age (GA) from 15 to 28 wee

Comparison of gradient encoding schemes
✍ Khader M. Hasan; Dennis L. Parker; Andrew L. Alexander 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 254 KB

## Abstract The accuracy of single diffusion tensor MRI (DT‐MRI) measurements depends upon the encoding scheme used. In this study, the diffusion tensor accuracy of several strategies for DT‐MRI encoding are compared. The encoding strategies are based upon heuristic, numerically optimized, and regu