𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Single breath-hold diffusion-weighted imaging of the abdomen

✍ Scribed by Lawrence C. Chow; Roland Bammer; Michael E. Moseley; F. Graham Sommer


Publisher
John Wiley and Sons
Year
2003
Tongue
English
Weight
502 KB
Volume
18
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To generate high quality diffusion‐weighted images (DWI) and corresponding isotropic ADC maps of the abdomen with full organ (kidneys) coverage in a single breath‐hold.

Materials and Methods

DWI was performed in 12 healthy subjects with an asymmetric, spin‐echo, single‐shot EPI readout on a system with high performance gradients (40 mT/minute). The isotropic diffusion coefficient 〈D〉 was measured from 〈D〉 maps and SNR was determined for both diffusion‐weighted and reference images in the liver, spleen, pancreas, and kidneys. In six patients, single‐axis diffusion encoding along three orthogonal axes (12 NEX) was employed to assess anisotropic diffusion in kidneys.

Results

This technique yielded images of quality and resolution which compares favorably to that of prior work. SNR ranged from 27.0 in liver to 44.1 in kidneys for the diffusion‐weighted images, and from 19.6 in liver to 39.0 in kidneys in reference images. ADCs obtained in the renal medulla, renal cortex, liver, spleen, and pancreas were (2091 ± 55) × 10^−6^, (2580 ± 53) × 10^−6^, (1697 ± 52) × 10^−6^, (1047 ± 82) × 10^−6^, and (2605 ± 168) × 10^−6^ mm^2^/second, respectively (mean ± SE). Apparent diffusion coefficient (ADC) in the renal medulla and cortex were significantly different by paired t‐test (P = 4.22 × 10^−10^). Renal medulla and cortex yielded anisotropy indices (AI) of 0.129 and 0.067, respectively.

Conclusions

  1. Single‐shot SE EPI DWI in the abdomen with this technique provides high quality images and 〈D〉 maps with full organ coverage in a single breath‐hold; 2) ADCs obtained in the renal medulla and cortex are significantly different; and 3) diffusion within the renal medulla is moderately anisotropic. J. Magn. Reson. Imaging 2003;18:377–382. © 2003 Wiley‐Liss, Inc.

📜 SIMILAR VOLUMES


Invited. Ultrafast MR imaging of the abd
✍ Yasuyuki Yamashita; Yi Tang; Mutsumasa Takahashi 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 939 KB

## Abstract Ultrafast MRI technique has become available with the introduction of new generation MR scanners for abdominal imaging. However, there is no consensus about the optimal imaging acquisition at the present time. Because single shot echo planar imaging (EPI) technique is based on high tech

Comparison of breath-hold T1-weighted MR
✍ Richard C. Semelka; Ann Bagley Willms; Mark A. Brown; Elizabeth D. Brown; J. Pau 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 910 KB

## Abstract Three rapid T1‐weighted gradient‐echo techniques for imaging of the liver were compared: fast low‐angle shot (FLASH) and section‐selective (SSTF) and non‐section‐selective (NSTF) inversion‐recovery TurboFLASH. Ten healthy volunteers were imaged at 1.5 T, with breath‐hold images acquired

Multishot diffusion-weighted SPLICE PROP
✍ Jie Deng; Reed A. Omary; Andrew C. Larson 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 594 KB

## Abstract Multishot FSE (fast spin echo)‐based diffusion‐weighted (DW)‐PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) MRI offers the potential to reduce susceptibility artifacts associated with single‐shot DW‐EPI (echo‐planar imaging) approaches. However,

Single breath-hold volumetric imaging of
✍ Piotr A. Wielopolski; Warren J. Manning; Robert R. Edelman 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 838 KB

## Abstract We show the feasibility of single breath‐hold volumetric imaging of the heart using a three‐dimensional (3D) segmented echo planar Imaging (EPI) pulse sequence. Fifteen healthy subjects were evaluated using three magnetization preparation schemes: (a) a driven equilibrium T2‐weighted pr