𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Selenium Determination in Biological Fluids Using Zeeman Background Correction Electrothermal Atomic Absorption Spectrometry

✍ Scribed by Natalia Campillo; Pilar Viñas; Ignacio López-Garcı́a; Manuel Hernández-Córdoba


Publisher
Elsevier Science
Year
2000
Tongue
English
Weight
67 KB
Volume
280
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


Procedures for the direct determination of total selenium in urine, serum, and blood using electrothermal atomic absorption spectrometry are presented. In the selected experimental conditions, Zeeman correction is mandatory to compensate for the high background signals. The sample diluted and containing 0.1% (w/v) Triton X-100 is introduced directly into the electrothermal atomizer. A solution containing 15% (w/v) hydrogen peroxide, 0.65% (w/v) nitric acid, and 0.5% (w/v) nickel is injected separately into the atomizer. Calibration is carried out using the standard additions method. The detection limit is 30 pg selenium. If palladium, instead of nickel, is used as the chemical modifier, calibration can be carried out against aqueous standards, and the detection limit is 45 pg. In this case, three separate injections are required to prevent precipitation problems in the automatic injector. The reliability of the procedures is checked by analyzing three certified reference materials and by recovery studies. Mean recoveries are 99.7% for serum, 99.4% for urine, and 100.8% for blood samples. Relative standard deviation values are +/-4.0% for serum, +/-3.9% for urine, and +/-4.5% for blood.


📜 SIMILAR VOLUMES


Determination of Cadmium in Wines Using
✍ James Jaganathan; Alan L. Reisig; Sumer M. Dugar 📂 Article 📅 1997 🏛 Elsevier Science 🌐 English ⚖ 77 KB

A graphite furnace atomic absorption spectrometry method with Zeeman background correction for the direct determination of cadmium in grape wines is described. Use of ammonium dihydrogen phosphate, magnesium nitrate, and palladium nitrate as matrix modifiers was investigated. Palladium nitrate with

Comparison of Zeeman background correcte
✍ Skipor, A. K. ;Jacobs, J. J. ;Yu, L. ;Black, J. 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 68 KB 👁 2 views

There is continued interest in the measurement of degradation products of metallic implants in biological tissues and fluids. A study was conducted to compare analytical results obtained by the Zeeman Background Corrected Atomic Absorption Spectrometric and Inductively Coupled Plasma Mass Spectromet

Atomization Characteristic of Chromium o
✍ Kiyohisa Ohta; Hiroya Uegomori; Syn-ichi Itoh; Takayuki Mizuno 📂 Article 📅 1997 🏛 Elsevier Science 🌐 English ⚖ 110 KB

Atomization characteristics of chromium have been studied by electrothermal atomic absorption spectrometry with a molybdenum tube atomizer. The appearance temperature (T app ) of chromium nitrate was 1300ЊC. The T app was independent of the heating rate of atomizer, but the temperature at the peak o

Robotic sample pretreatment coupled with
✍ Alfredo Velasco-Arjona; María Dolores Luque de Castro; Elissaveta Ivanova; Fredd 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 172 KB 👁 2 views

An automated robotic method for sample pretreatment was developed for copper determination in environmental and biological materials at the low microgram per gram level. The robotic station performing the preliminary operations as weighing of sample and acid digestion was coupled with the flowinject