𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Selective retention of catecholamines and their derivatives reversed-phase ion-pair partition chromatography

✍ Scribed by J. De Jong; C.F.M. van Valkenburg; U.R. Tjaden


Publisher
Elsevier Science
Year
1985
Tongue
English
Weight
720 KB
Volume
322
Category
Article
ISSN
1873-3778

No coin nor oath required. For personal study only.

✦ Synopsis


Some possibilities are described to improve the separation between catecholamines and their corresponding metanephrines in reversed-phase ion-pair partition chromatography. The retention of amines can be influenced by the perchlorate concentration of the mobile phase, while the retention of acidic metabolites is governed by the pH of the mobile phase. Nevertheless, a separation between the catecholamines and their corresponding metanephrines cannot be achieved by optimizing these mobile phase parameters. A decrease in the temperature of the chromatographic system leads to an improvement in the separation between dopamine and 3-methoxytyramine; however, adrenaline and noradrenaline are not separated from metanephrine and normetanephrine, respectively, and the chromatographic efficiency decreases. Addition of boric acid to the mobile phase results in a selective decrease in the retention of compounds with a catechol function, the magnitude of this effect depending on the mobile phase pH. Applying this "boric acid effect" it is possible to obtain a complete and rapid separation (within about 9 min) of the catecholamines, their corresponding metanephrines, the acidic metabolites homovanillic acid and 3,4-d& hydroxyphenylacetic acid and the neutral metabolite 3-methoxy4hydroxyphenylethylene glycol.


πŸ“œ SIMILAR VOLUMES


Reversed-phase ion-pair liquid chromatog
✍ Morgan Stefansson; Douglas Westerlund πŸ“‚ Article πŸ“… 1990 πŸ› Elsevier Science 🌐 English βš– 664 KB

The parameters that influence the retention and selectivity of glucuronides in reversed-phase ion-pair liquid chromatography were investigated. The extent of ion-pair retention was dependent on the degree of substitution of the ammonium counter ion used and increased in the order 4-< 2-< 3-< l-subs

Reversed-phase ion-pair partition chroma
✍ Karl-Gustav Wahlund πŸ“‚ Article πŸ“… 1975 πŸ› Elsevier Science 🌐 English βš– 813 KB

A reversed-phase partition chrematographic system for separation of organic ations as ion pairs with qnatemary ammonium ions has been developed. Commercia!, hydrophobized silica supports are used wi& I-pentanol as st&ianzy phase and aqueocs solutions of tetrabutylammoGum (TBA) = mobile phase. The se