𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Selective detection of phosphopeptides in complex mixtures by electrospray liquid chromatography/mass spectrometry

✍ Scribed by Michael J. Huddleston; Roland S. Annan; Mark F. Bean; Steven A. Carr


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
821 KB
Volume
4
Category
Article
ISSN
1044-0305

No coin nor oath required. For personal study only.

✦ Synopsis


A mass spectrometry-based method that does not involve the use of radiolabeling was developed for selective detection of phosphopeptides in complex mixtures. Mixtures of phosphorylated and nonphosphorylated peptides at the low picomole level are analyzed by negative ion electrospray liquid chromatography/mass spectrometry using C-18 packed fused-silica columns (≤320-μm i.d.). Peptides and phosphopeptides in the chromatographic eluant undergo collision-induced dissociation in the free-jet expansion region prior to the mass analyzing quadrupole. Using relatively high collisional excitation potentials, phospho|peptides containing phosphoserine, phosphothreonine, and phosphotyrosine fragment to yield diagnostic ions at m/z 63 and 79 corresponding to PO2 (-); and PO3 (-), respectively. Chromatographic peaks containing phosphopeptides are indicated where these diagnostic ions maximize. The highest sensitivity for phosphopeptide detection is obtained using selected-ion monitoring for m/z 63 and 79. Full-scan mass spectra that exhibit the diagnostic phosphopeptide fragment ions, together with pseudomolecular ions, may be obtained by stepping the collisional excitation potential from a high value during the portion of each scan in which the low-mass-to-charge ratio diagnostic marker ions are being detected to a lower value while the upper mass-to-charge ratio range is being scanned. Good sensitivity for phosphopeptide detection was achieved using standard trifluoroacetic acid containing mobile phases for reversed-phase high-performance liquid chromatography. Data illustrating the selectivity and sensitivity of the approach are presented for mixtures of peptides and phosphopeptides containing the three commonly phosphorylated amino acids.


📜 SIMILAR VOLUMES


Gallium metal affinity capture tandem ma
✍ Grady R. Blacken; Martin Sadílek; František Tureček 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 317 KB

## Abstract Metal affinity capture tandem mass spectrometry (MAC‐MSMS) is evaluated in a comparative study of a lysine‐derived nitrilotriacetic acid (__N__~α~, __N__~α~‐bis‐(carboxymethyl)lysine, LysNTA) and an aspartic‐acid‐related iminodiacetic acid (__N__‐(4‐aminobutyl)aspartic acid, AspIDA) as

Determination of clenbuterol residues by
✍ Laurent Debrauwer; Georges Bories 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 764 KB

The apphcatlon of electrospray lonlzatlon to the mass spectrometnc determmatlon of clenbuterol was mvestrgated Usmg electrospray, the energy of the eons extracted mto the vacuum system can be controlled and, therefore, colhs~onally actuated chssoclations (with residual gas) can be Induced m the h&-p

Electrospray ionization mass spectrometr
✍ Lydia M. Nuwaysir; John T. Stults 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 870 KB

Electrospray ionization mass spectrometry (ESI/MS) affords a rapid and sensitive technique for determining peptides produced by the enzymatic digestion of phosphoroteins. When coupled with on-line immobilized metal-ion affinity chromatography (IMAC), the combmation allows separation and mass spectro