## Aldosterone was derivatized as butane boronate cyclic ester. This derivative gives an intense molecular ion under 70-eV electron impact conditions. This ion exhibits an abundant metastable decomposition in the second field free region by loss of formic acid, which can be used for the assay. A l
Gallium metal affinity capture tandem mass spectrometry for the selective detection of phosphopeptides in complex mixtures
✍ Scribed by Grady R. Blacken; Martin Sadílek; František Tureček
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 317 KB
- Volume
- 43
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1387
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Metal affinity capture tandem mass spectrometry (MAC‐MSMS) is evaluated in a comparative study of a lysine‐derived nitrilotriacetic acid (N~α~, N~α~‐bis‐(carboxymethyl)lysine, LysNTA) and an aspartic‐acid‐related iminodiacetic acid (N‐(4‐aminobutyl)aspartic acid, AspIDA) as selective phosphopeptide detection reagents. Both LysNTA and AspIDA spontaneously form ternary complexes with Ga^III^ and phosphorylated amino acids and phosphopeptides upon mixing in solution. Collision‐induced dissociation of positive complex ions produced by electrospray produces common fragments (LysNTA + H)^+^ or (AspIDA + H)^+^ at m/z 263 and 205, respectively. MSMS precursor scans using these fragments as reporter ions allow one to selectively detect multiple charge states of phosphopeptides in mixtures. It follows from this comparative study that LysNTA is superior to AspIDA in detecting phosphopeptides, possibly because of the higher coordination number and greater stability constant for Ga^III^—phosphopeptide complexation of the former reagent. In a continuing development of MAC‐MSMS for proteomics applications, we demonstrate its utility in a post‐column reaction format. Using a simple post‐column‐reaction ‘T’ and syringe pump to deliver our chelating reagents, α‐casein tryptic phosphopeptides can be selectively analyzed from a solution containing a twofold molar excess of bovine serum albumin. The MAC‐MSMS method is shown to be superior to the commonly used neutral loss scan for the common loss of phosphoric acid. Copyright © 2008 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
A method is described for the liquid chromatography/tandem mass spectrometry analysis of free base porphyrins, which allows the routine and rapid recognition of alkyl substituents in the components of complex natural mixtures. The method overcomes difficulties associated with probe tandem mass spect