𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Sample rotation during depth profiling with secondary ion mass spectrometry

✍ Scribed by John J. Vajo; Eun-Hee Cirlin


Publisher
John Wiley and Sons
Year
1991
Tongue
English
Weight
809 KB
Volume
17
Category
Article
ISSN
0142-2421

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Depth profiles obtained using secondary ion mass spectrometry with O~2~^+^ primary ions and without sample rotation have been measured for Mg‐implanted GaAs, B‐ and ^2^H‐implanted bulk Mo, a deposited Ni/SiO~2~ interface and for a molecular‐beam‐epitaxy‐grown structure consisting of monolayers of AIAs in GaAs. For the Mg‐implanted GaAs sample profiled without rotation, secondary ion yield changes associated with the development of surface ripples distorted both the matrix an implant profiles. Rotation of the sample during profiling prevented the formation of; surface ripples and, therefore, the associated yield changes. For the bulk Mo sample, surface roughness developed for both rotated and stationary samples. However, with sample rotation, the roughness was considerable reduced and, consequently, depth resolution for the implant profiles was improved. Similarly, the resolution of the Ni/SiO~2~ interface was greatly increased using sample rotation. For the monolayer AIAs/GaAs sample, profiles were obtained with low primary ion primary ion energy and large angle of incidence with respect to the surface normal in order to optimize the depth resolution. Under these conditions without sample rotation, uneven sputtering by spatially averaging the ion current density, thereby providing good depth resolution of the AIAs monolayers almost without degradation.


📜 SIMILAR VOLUMES


Application of sample rotation to second
✍ F. A. Stevie; J. L. Moore 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 English ⚖ 483 KB

## Abstract Aluminum films sputter‐deposited on silicon have been analyzed using secondary ion mass spectrometry with sample rotation during O~2~^+^ ion bombardment. Sample rotation prevented bombardment‐induced topography formation and associated loss of depth resolution. Analysis of silicon and b

Depth profile measurement by secondary i
✍ M. Moens; M. van Craen; F.C. Adams 📂 Article 📅 1984 🏛 Elsevier Science 🌐 English ⚖ 1022 KB

The possibilities of measuring depth profiles by secondary ion mass spectrometry are evaluated. The influence of different instrumental and experimental parameters on depth resolution in the profiles are studied: the effects of primary ion beam characteristics, reactive gas adsorption and mechanical