## Abstract Radiofrequency (RF) field inhomogeneity is an unavoidable problem in MRI, and it becomes severe at high magnetic fields due to the dependence of __B__~1~ on the sample. It leads to nonuniformities in image intensity and contrast, causing difficulties in quantitative interpretation and i
RF inhomogeneity compensation in structural brain imaging
✍ Scribed by R. Deichmann; C.D. Good; R. Turner
- Publisher
- John Wiley and Sons
- Year
- 2002
- Tongue
- English
- Weight
- 473 KB
- Volume
- 47
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Three‐dimensional T~1~‐weighted magnetization‐prepared rapid gradient‐echo (MP‐RAGE) sequences with centric phase encoding (PE) in the inner loop provide structural brain images with a high spatial resolution and high tissue contrast. A disadvantage of this sequence type is the susceptibility to inhomogeneities of the radiofrequency (RF) coil, which may result in poor image contrast in some peripheral regions. A special excitation pulse is presented which compensates for these effects in both the head/foot and anterior/posterior directions. This pulse has a duration of only 1.3 ms and is thus compatible with the short repetition times (TRs) required for MP‐RAGE imaging. It is shown experimentally that images acquired with the compensation pulse may be segmented without using intensity correction algorithms during data postprocessing. Magn Reson Med 47:398–402, 2002. © 2002 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
We evaluated two methods for correcting inhomogeneity-induced signal losses in magnetic resonance gradient-echo imaging that either use gradient compensation or simply acquire thin sections. The strategies were tested in the human brain in terms of achievable quality of T2\*-weighted images at the l
## Abstract In images acquired by confocal laser scanning microscopy (CLSM), regions corresponding to the same concentration of fluorophores in the specimen should be mapped to the same grayscale levels. However, in practice, due to multiple distortion effects, CLSM images of even homogeneous speci
## Abstract ## Purpose: To reliably compensate bias field effects in abdominal areas to accurately quantify visceral adipose tissue using standard T1‐weighted sequences on MR scanners with up to 3 Tesla (T) field strength. ## Materials and Methods: Compensation is achieved in two steps: The bias
## Abstract MRI has evolved into an important diagnostic technique in medical imaging. However, reliability of the derived diagnosis can be degraded by artifacts, which challenge both radiologists and automatic computer‐aided diagnosis. This work proposes a fully‐automatic method for measuring imag