𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Resolution in High Field Echo Planar Microscopy

✍ Scribed by A.M. Peters; R. Bowtell


Publisher
Elsevier Science
Year
1999
Tongue
English
Weight
883 KB
Volume
137
Category
Article
ISSN
1090-7807

No coin nor oath required. For personal study only.

✦ Synopsis


The application of echo planar imaging to NMR microscopy offers a temporal resolution unparalleled by other techniques. However, a major difficulty in imaging at the high field strengths used for microscopy is the effect of local field inhomogeneities caused by magnetic susceptibility effects. This can give rise to both image distortion and signal loss. In addition, the effect of diffusion in the presence of the large imaging gradients gives rise to a broadening of the point spread function and hence loss of true resolution. We compare the sensitivity of two techniques, MBEST and PEPI, to both of these effects. Analytic expressions for the signal in each echo of the two sequences are developed, and the point spread functions for the two techniques are calculated. Using PEPI, we have been able to produce images with an in-plane resolution of 50 m from a single free induction decay. This technique has been extended to three dimensions allowing the generation of 64 3 images with an isotropic resolution of 80 m.


📜 SIMILAR VOLUMES


Echo-planar high-resolution flow velocit
✍ D. N. Firmin; R. H. Klipstein; G. L. Hounsfield; M. P. Paley; D. B. Longmore 📂 Article 📅 1989 🏛 John Wiley and Sons 🌐 English ⚖ 598 KB

A technique for the very rapid measurement of blood flow with high spatial resolution is described. The method combines the previously validated technique of phase velocity mapping and echo-planar principles. The relatively small diameter of blood vessels enables a high-resolution echo-planar flow m

High-Field MR microscopy using fast spin
✍ Xiaohong Zhou; Gary P. Cofer; Steve A. Suddarth; G. Allan Johnson 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 910 KB

## Abstract Fast spin‐echo imaging has been investigated with attention to the requirements and opportunities for high‐field MR microscopy. Two‐and three‐dimensional versions were implemented at 2.0 T, 7.1 T, and 9.4 T. At these fields, at least eight echoes were collectable with a 10 ms __TE__ fro

Spin-echo fMRI in humans using high spat
✍ Essa Yacoub; Timothy Q. Duong; Pierre-Francois Van De Moortele; Martin Lindquist 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 851 KB

## Abstract The Hahn spin‐echo (HSE)‐based BOLD effect at high magnetic fields is expected to provide functional images that originate exclusively from the microvasculature. The blood contribution that dominates HSE BOLD contrast at low magnetic fields (e.g., 1.5 T), and degrades specificity, is hi

High-resolution echo-planar fMRI of huma
✍ Keith R. Thulborn; Sam Y. Chang; Gary X. Shen; James T. Voyvodic 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 226 KB 👁 2 views

Known specialized properties of the human visual cortex have been used to investigate the role of spatial resolution on fMRI using blood oxygenation level dependent (BOLD) echo-planar MRI at 3.0 tesla. The magnitude of BOLD signal changes has been examined at low (3.1ϫ 3.1ϫ 3.0 mm 3 ) and high (0.8ϫ

FIESTA-ET: High-resolution cardiac imagi
✍ Glenn S. Slavin; Manojkumar Saranathan 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 408 KB

This work describes a technique that combines multishot echo-planar imaging (EPI) with steady-state free precession (SSFP, also known as TrueFISP, FIESTA, and balanced FFE) for multislice, cine MR imaging of the heart. Unlike recently reported methods, the technique presented here (FIESTA-ET) is hig