𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields

✍ Scribed by Essa Yacoub; Timothy Q. Duong; Pierre-Francois Van De Moortele; Martin Lindquist; Gregor Adriany; Seong-Gi Kim; Kâmil Uğurbil; Xiaoping Hu


Publisher
John Wiley and Sons
Year
2003
Tongue
English
Weight
851 KB
Volume
49
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The Hahn spin‐echo (HSE)‐based BOLD effect at high magnetic fields is expected to provide functional images that originate exclusively from the microvasculature. The blood contribution that dominates HSE BOLD contrast at low magnetic fields (e.g., 1.5 T), and degrades specificity, is highly attenuated at high fields because the apparent T~2~ of venous blood in an HSE experiment decreases quadratically with increasing magnetic field. In contrast, the HSE BOLD contrast is believed to arise from the microvasculature and increase supralinearly with the magnetic field strength. In this work we report the results of detailed and quantitative evaluations of HSE BOLD signal changes for functional imaging in the human visual cortex at 4 and 7 T. This study used high spatial resolution, afforded by the increased signal‐to‐noise ratio (SNR) of higher field strengths and surface coils, to avoid partial volume effects (PVEs), and demonstrated increased contrast‐to‐noise ratio (CNR) and spatial specificity at the higher field strengths. The HSE BOLD signal changes induced by visual stimulation were predominantly linearly dependent on the echo time (TE). They increased in magnitude almost quadratically in going from 4 to 7 T when the blood contribution was suppressed using Stejskal‐Tanner gradients that suppress signals from the blood due to its inhomogeneous flow and higher diffusion constant relative to tissue. The HSE signal changes at 7 T were modeled accurately using a vascular volume of 1.5%, in agreement with the capillary volume of gray matter. Furthermore, high‐resolution acquisitions indicate that CNR increased with voxel sizes < 1 mm^3^ due to diminishing white matter or cerebrospinal fluid‐space vs. gray matter PVEs. It was concluded that the high‐field HSE functional MRI (fMRI) signals originated largely from the capillaries, and that the magnitude of the signal changes associated with brain function reached sufficiently high levels at 7 T to make it a useful approach for mapping on the millimeter to submillimeter spatial scale. Magn Reson Med 49:655–664, 2003. © 2003 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Spatial location and strength of BOLD ac
✍ J. Harmer; R. M. Sanchez-Panchuelo; R. Bowtell; S. T. Francis 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 484 KB

The increased blood oxygenation level-dependent contrast-to-noise ratio at ultrahigh field (7 T) has been exploited in a comparison of the spatial location and strength of activation in high-resolution (1.5 mm isotropic) gradient echo (GE) and spin echo (SE), echo planar imaging data acquired during

Rotational spin echoes and high resoluti
✍ Matti Maricq; J.S. Waugh 📂 Article 📅 1977 🏛 Elsevier Science 🌐 English ⚖ 276 KB

When a powder having linewidth A arising from inhomogeneous second-rank tensor interactions is rotated about the magic axis at trot < A, the free induction decay is a spin echo train, the Fourier transform of whose envelope is the isotropic spectrum. In obtaining isotropic chemical shift spectra of

Comparison of diffusion-weighted high-re
✍ Sang-Pil Lee; Afonso C. Silva; Seong-Gi Kim 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 485 KB

## Abstract The quantification of blood oxygenation‐level dependent (BOLD) functional MRI (fMRI) signals is closely related to cerebral blood flow (CBF) change; therefore, understanding the exact relationship between BOLD and CBF changes on a pixel‐by‐pixel basis is fundamental. In this study, quan

High-resolution human in vivo spectrosco
✍ H. W. Park; Z. H. Cho 📂 Article 📅 1986 🏛 John Wiley and Sons 🌐 English ⚖ 420 KB

A high-resolution human in vivo spectroscopic image was obtained using the 2.0-T NMR imaging system developed at KAIS (Korea Advanced Institute of Science). The in vivo spectroscopic image obtained has high spatial resolution as well as spectral resolution good enough for extraction of the detailed

Reproducibility of high spatial resoluti
✍ H. Cecil Charles; François Lazeyras; Larry A. Tupler; Dr. K. Ranga R. Krishnan 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 350 KB 👁 1 views

## Abstract The application of proton (^1^H) magnetic resonance spectroscopic imaging (MRSI) allows for noninvasive, localized analyses of brain biochemistry; however, minimal work has been devoted to the evaluation of ^1^H MRSI reproducibility. This study examined the reproducibility of ^1^H MRSI