## Abstract A diffusion‐weighted fast spin‐echo (FSE) imaging sequence for high‐field MR microscopy was developed and experimentally validated in a phantom and in a live rat. Pulsed diffusion gradients were executed before and after the initial 180° pulse in the FSE pulse train. This produced diffu
High-Field MR microscopy using fast spin-echoes
✍ Scribed by Xiaohong Zhou; Gary P. Cofer; Steve A. Suddarth; G. Allan Johnson
- Publisher
- John Wiley and Sons
- Year
- 1993
- Tongue
- English
- Weight
- 910 KB
- Volume
- 30
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Fast spin‐echo imaging has been investigated with attention to the requirements and opportunities for high‐field MR microscopy. Two‐and three‐dimensional versions were implemented at 2.0 T, 7.1 T, and 9.4 T. At these fields, at least eight echoes were collectable with a 10 ms TE from fixed tissue specimens and living animals, giving an eightfold improvement in imaging efficiency. To reduce the phase‐encoding gradient amplitude and its duty cycle, a modified pulse sequence with phase accumulation was developed. Images obtained using this pulse sequence exhibited comparable signal‐to‐noise (SNR) to those obtained from the conventional fast spin‐echo pulse sequences. Signal losses due to imperfections in RF pulses and lack of phase rewinders were offset in this sequence by reduced diffusion losses incurred with the gradients required for MR microscopy. Image SNR, contrast, edge effects and spatial resolution for three k‐space sampling schemes were studied experimentally and theoretically. One method of sampling k‐space, 4‐GROUP FSE, was found particularly useful in producing varied T~2~ contrast at high field. Two‐dimensional images of tissue specimens were obtained in a total acquisition time of 1 to 2 min with in‐plane resolution between 30 to 70 μm, and 3D images with 256^3^ arrays were acquired from fixed rat brain tissue (isotropic voxel = 70 μm) and a living rat (isotropic voxel = 117 μm) in∼4.5 h.
📜 SIMILAR VOLUMES
## Abstract Distinguishing between lipid and water‐containing tissues is clinically important. Current techniques rely on the chemical shift difference between fat and water resonances or differences in relaxation times of the tissues, or a combination of both. A method is presented for separating
## Abstract Magnetic resonance imaging is frequently complicated by the presence of motion and susceptibility gradients. Also, some biologic tissues have short T2s. These problems are particularly troublesome in fast spin‐echo (FSE) imaging, in which T2 decay and motion between echoes result in ima
The application of echo planar imaging to NMR microscopy offers a temporal resolution unparalleled by other techniques. However, a major difficulty in imaging at the high field strengths used for microscopy is the effect of local field inhomogeneities caused by magnetic susceptibility effects. This
## Abstract To evaluate the feasibility of MR colonography (MRC) with air using two‐dimensional (2D) T1‐weighted fast spin‐echo (T1wFSE) in patients scheduled for conventional colonoscopy (CC) after classic bowel preparation, and assess the ability of the technique to detect colonic lesions. The di
## Abstract The Hahn spin‐echo (HSE)‐based BOLD effect at high magnetic fields is expected to provide functional images that originate exclusively from the microvasculature. The blood contribution that dominates HSE BOLD contrast at low magnetic fields (e.g., 1.5 T), and degrades specificity, is hi