𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Research on Reliability for Linkage Control of Automatic Sprinkling Pump System

✍ Scribed by CHEN Ji-bin; CAO Xiang-hong


Publisher
Elsevier
Year
2011
Tongue
English
Weight
184 KB
Volume
11
Category
Article
ISSN
1877-7058

No coin nor oath required. For personal study only.

✦ Synopsis


Water supply pump is the heart of automatic sprinkler system and should start reliably when there is on fire. But because sprinkler system and automatic fire alarm system related to linkage control of water supply pump are designed by different manufacturers and installed by skillful staffs in different fields, there are accident potentials existing in the low reliability linkage control. The failure probability of extinguishment system is higher. In this paper, research on reliability and linkage control of automatic sprinkling pump system has been carried out. Intermediate link has been eliminated. Strong and weak electricity are isolated. Automatic and manual controls are combined. Redundancy technique is used. A linkage control system for water supply pump with high reliability and economical efficiency has been designed. Our achievement has been applied in many fire fighting systems and the linkage control system of water supply pump is proved to be safe and reliable.


πŸ“œ SIMILAR VOLUMES


Automatic control of installations for e
✍ F van der Mark; J.H.C Meijer πŸ“‚ Article πŸ“… 1974 πŸ› Elsevier Science βš– 448 KB

A mini-computer controls several installations where rabbits perform pattern-discrimination tests. Each installation runs independently of the others, permitting each rabbit to behave at its own speed (which is an essential part of the test). The number of installations can easily be extended withou

Research and technical notes: A system f
✍ B.A. Ivanov πŸ“‚ Article πŸ“… 1964 πŸ› Elsevier Science 🌐 English βš– 74 KB

T s E proposed system controls nitrogen flow, providing a stable deep cooling of circulating traps for diffusion pumps. The necessary pressure is maintained in a Dewar by means of an automatic valve and a heater on the nitrogen line, and as the nitrogen reserve is exhausted a signal is switched on.

Interface requirements, transducers and
✍ T.J. Williams πŸ“‚ Article πŸ“… 1969 πŸ› Elsevier Science 🌐 English βš– 929 KB

Exigences vis h vis des matdriels p6riph6riques, des capteurs et des calculateurs pour les syst~mes de rdglage StoBstellenanforderungen, Wandler und Rechner far on-line-Systeme Tpe6oBaH14n rtpezi~B.naeMble r nepx, Iqbepx,lqeCroMy o6opy/IoBaHmo, r )IaTqnKaM 14 K BblHI4CMPITeMbHbIM yCTpOfiCTBaM )I.rI~