The current study sought to investigate the reproducibility of a quantitative spectroscopic examination, using rigorous positioning guidelines and automated spectral fitting for measuring the cerebral metabolites N-acetylaspartate (NAA), creatine (Cre), choline (Cho), and myo-inositol (ml). Ten subj
Reproducibility of 1H-MRS measurements in schizophrenic patients
✍ Scribed by Paul G. Mullins; Laura Rowland; Juan Bustillo; Edward J. Bedrick; John Lauriello; William M. Brooks
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 139 KB
- Volume
- 50
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The reproducibility of single‐voxel spectroscopic measures in a stable schizophrenic patient population is reported. Spectra acquired 1 week apart, in the left frontal white matter and left caudate nucleus of 12 patients, were analyzed using both frequency and time‐domain techniques. No significant change in mean concentrations for N‐acetylaspartate (NAA), choline (Cho), and creatine (Cre) were found between sessions. Variation from scan to scan was low for the left frontal white matter, with coefficients of variation (CV) < 5% for all three metabolites. NAA measures from the left caudate nucleus had similar reproducibility (CV = 5%), but Cho and Cre were poorer by comparison (CV = 16–18%). The two methods used for spectral analyses produced similar results, indicating that both techniques are appropriate. These results extend previous studies of healthy, normal subjects, and establish that it is possible to obtain reliable measures of brain metabolites in clinical populations. Magn Reson Med 50:704–707, 2003. © 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract The reproducibility of metabolite content determined by MR spectroscopy (MRS) is usually at best a few percent for the prominent singlets. When studying low‐concentration metabolites, like phenylalanine (Phe), where tissue content can be <100 μmol/kg, better reproducibility is paramount
## Abstract ## Purpose To determine the reproducibility of proton (^1^H) magnetic resonance (MR) spectroscopy and dynamic contrast‐enhanced MR imaging in a clinical setting for the assessment of marrow fat fraction and marrow perfusion in longitudinal studies. ## Materials and Methods In all, 36
## Abstract ## Purpose To assess the intra‐ and interobserver agreement of commonly reported foot structure measurements in diabetic patients with neuropathy using magnetic resonance imaging (MRI). ## Materials and Methods In 23 neuropathic diabetic patients and five age‐matched healthy controls
## Abstract ## Purpose: To determine the reproducibility of 3D proton magnetic resonance spectroscopic imaging (^1^H‐MRSI) of the human prostate in a multicenter setting at 1.5T. ## Materials and Methods: Fourteen subjects were measured twice with 3D point‐resolved spectroscopy (PRESS) ^1^H‐MRSI