𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Reference distributions for the negative acute-phase proteins, albumin, transferrin, and transthyretin: A comparison of a large cohort to the world's literature

✍ Scribed by Robert F. Ritchie; Glenn E. Palomaki; Louis M. Neveux; Olga Navolotskaia


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
110 KB
Volume
13
Category
Article
ISSN
0887-8013

No coin nor oath required. For personal study only.

✦ Synopsis


Clinical interpretation of the acute-phase proteins-albumin, transferrin, and transthyretin-has been hampered by the lack of accurate and precise methods for quantifying the levels and a stable and respected reference material. Now that these issues have been addressed, the community is faced with the need for credible age-and gender-specific reference values. The number of publications that address this issue, even for an analyte as familiar as albumin, is small and, in most cases, such publications lack the relevant data that would allow a combined experience to be created. We have identified 40 studies that meet our criteria: a description of the study participants' health status, of the statistical methodology, and of the laboratory technique and/or reference material used. Few of these studies reported values stratified by gender. A summary of the published median levels by age is presented for the three analytes, along with our own age-and gender-specific medians based on a large cohort. Ten of the studies presented a 95 percent reference range, in close agreement with ours where selection was based upon reported diagnosis rather than upon determination of individual health status. This meta-analysis provides support for the reliability of our recently published methodology and reference data for the clinical interpretation of individual albumin, transferrin, and transthyretin values. As with most laboratory measurements, clinical interpretation requires that other laboratory and clinical factors be considered.


πŸ“œ SIMILAR VOLUMES


Reference distributions for the negative
✍ Robert F. Ritchie; Glenn E. Palomaki; Louis M. Neveux; Olga Navolotskaia; Thomas πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 125 KB πŸ‘ 1 views

Inflammation is associated with diverse clinical conditions accompanied by characteristic changes in serum levels of the acutephase proteins that can be used to stage the inflammatory process and evaluate the impact of treatment. Some acute-phase proteins increase during inflammation, while others,

Reference distributions for serum iron a
✍ Robert F. Ritchie; Glenn E. Palomaki; Louis M. Neveux; Olga Navolotskaia; Thomas πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 122 KB

## Abstract The appropriate clinical use of serum iron and transferrin saturation (TSAT) requires satisfactory reference intervals from birth to old age, and for males and females. This study identified 54 publications from 1974 to 2001 that met the criteria used in three prior meta‐analyses, and t

Reference distributions for Ξ±2-macroglob
✍ Robert F. Ritchie; Glenn E. Palomaki; Louis M. Neveux; Olga Navolotskaia πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 79 KB

## Abstract The lack of satisfactory methods for quantifying serum levels and a credible reference material has limited bedside use of serum alpha~2~‐macroglobulin (Ξ±2M) measurements. Great strides have been made in the last few years. The remaining barrier to more relevant and cost effective use o

Reference distributions for complement p
✍ Robert F. Ritchie; Glenn E. Palomaki; Louis M. Neveux; Olga Navolotskaia πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 86 KB

## Abstract The lack of credible reference materials and satisfactory methods for quantifying serum levels has limited the bedside use of complement protein (C3 and C4) measurements. However, great technological strides have been made in the last few years. The remaining barrier to a more relevant

Reference distributions for immunoglobul
✍ Robert F. Ritchie; Glenn E. Palomaki; Louis M. Neveux; Olga Navolotskaia πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 81 KB πŸ‘ 1 views

Clinical interpretation of immunoglobulin measurements requires accurate and precise assays and widely accepted reference preparations, as well as reliable age- and gender-specific reference ranges. This last requirement, the topic of numerous publications, has not been addressed adequately. By a co