## Abstract The lack of satisfactory methods for quantifying serum levels and a credible reference material has limited bedside use of serum alpha~2~‐macroglobulin (α2M) measurements. Great strides have been made in the last few years. The remaining barrier to more relevant and cost effective use o
Reference distributions for complement proteins C3 and C4: A comparison of a large cohort to the world's literature
✍ Scribed by Robert F. Ritchie; Glenn E. Palomaki; Louis M. Neveux; Olga Navolotskaia
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 86 KB
- Volume
- 18
- Category
- Article
- ISSN
- 0887-8013
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The lack of credible reference materials and satisfactory methods for quantifying serum levels has limited the bedside use of complement protein (C3 and C4) measurements. However, great technological strides have been made in the last few years. The remaining barrier to a more relevant and cost‐effective use of serum protein data for diagnosis and prognosis is the availability of reliable reference intervals from birth to old age for both males and females. Fifty‐one publications reporting reference intervals were identified that meet the criteria used in our prior four studies, and these were analyzed statistically. Previous small studies with constrained age ranges agree, on average, with our larger series of life‐long reference ranges. This meta‐analysis provides support for our reference ranges and places them in the context of previous publications. J. Clin. Lab. Anal. 18:9–13, 2004. © 2004 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract The two serum proteins of the complement cascade in the highest concentrations, C3 and C4, respond to various conditions in much the same manner as do other positive acute‐phase proteins. A major difference is that they are relatively sluggish in response to cytokine drive, requiring se
Clinical interpretation of immunoglobulin measurements requires accurate and precise assays and widely accepted reference preparations, as well as reliable age- and gender-specific reference ranges. This last requirement, the topic of numerous publications, has not been addressed adequately. By a co
## Abstract The appropriate clinical use of serum iron and transferrin saturation (TSAT) requires satisfactory reference intervals from birth to old age, and for males and females. This study identified 54 publications from 1974 to 2001 that met the criteria used in three prior meta‐analyses, and t
Clinical interpretation of the acute-phase proteins-albumin, transferrin, and transthyretin-has been hampered by the lack of accurate and precise methods for quantifying the levels and a stable and respected reference material. Now that these issues have been addressed, the community is faced with t
## Abstract Limiting the clinical utility of apolipoproteins AI (apo AI) and B (apo B) and the apo B/AI ratios until the last decade has been the lack of satisfactory methods for quantifying serum levels and credible reference materials. Great technological strides have been made in the last few ye