𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Real-time functional MRI using a PC cluster

✍ Scribed by Bagarinao, Epifanio ;Matsuo, Kayako ;Nakai, Toshiharu


Publisher
John Wiley and Sons
Year
2003
Tongue
English
Weight
599 KB
Volume
19B
Category
Article
ISSN
1043-7347

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A system for the real‐time analysis of functional magnetic resonance imaging (fMRI) time series is evaluated. The system exploits the advantages of parallel computing, coupled with an efficient general linear model (GLM) coefficient estimation algorithm, to overcome several issues constraining the analysis of the whole‐brain fMRI data in real time. The highly parallel, voxel‐wise processing of fMRI data motivated the use of a cluster of personal computers for parallel computation. Aside from gaining a significant increase in computational speed, the PC cluster provides a versatile way to handle the computational requirements of the system. The use of GLM in the supporting software allows substantial parametric analysis to be performed. Results of the real‐time analysis of the whole‐brain fMRI data of a normal subject performing a simple finger‐tapping task demonstrated the capabilities of the system. For a real‐time statistical analysis including real‐time image reconstruction, realignment for motion correction, smoothing, GLM coefficient estimation, statistical analysis, and update of the displayed activation map, the time required to process the data for each image volume is about 1.034 s for a 64 × 64 × 30 image volume and 2.561 s for a 128 × 128 × 20 image volume, less than the TR set to 3 s. © 2003 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 19B: 14–25, 2003.


📜 SIMILAR VOLUMES


Intraoperative, real-time, functional MR
✍ David T. Gering; David M. Weber 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 618 KB

Functional MRI (fMRI) methods have been demonstrated to noninvasively identify motor-sensory, visual, and other areas of eloquent cortex for guiding surgical intervention. Typically, fMRI data are acquired preoperatively during a conventional surgical planning MRI examination. Unlike direct cortical

Real-time black-blood MRI using spatial
✍ Krishna S. Nayak; Pedro A. Rivas; John M. Pauly; Greig C. Scott; Adam B. Kerr; B 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 219 KB

## Abstract A real‐time interactive black‐blood imaging system is described. Rapid blood suppression is achieved by exciting and dephasing slabs outside the imaging slice before each imaging excitation. Sharp‐profiled radio frequency saturation pulses placed close to the imaging slice provide good

Rapid ventricular assessment using real-
✍ Krishna S. Nayak; John M. Pauly; Dwight G. Nishimura; Bob S. Hu 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 189 KB

A multislice real-time imaging technique is described which can provide continuous visualization of the entire left ventricle under resting and stress conditions. Three dynamically adjustable slices containing apical, mid, and base short axis views are imaged 16 times/sec (48 images/sec), with each

Real-time motion detection in spiral MRI
✍ Todd S. Sachs; Craig H. Meyer; Bob S. Hu; Jim Kohli; Dwight G. Nishimura; Albert 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 691 KB

## Abstract A technique has been developed whereby motion can be detected in real time during the acquisition of data. This enables the implementation of an algorithm to accept or reject and reacquire data during a scan. Frames of data with motion are rejected and reacquired on the fly so that by t

Whole-heart cine MRI using real-time res
✍ Sergio Uribe; Vivek Muthurangu; Redha Boubertakh; Tobias Schaeffter; Reza Razavi 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 486 KB

## Abstract Two‐dimensional (2D) breath‐hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three‐dimensional (3D) cardiac MR can overcome some of thes