𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Real-time motion detection in spiral MRI using navigators

✍ Scribed by Todd S. Sachs; Craig H. Meyer; Bob S. Hu; Jim Kohli; Dwight G. Nishimura; Albert Macovski


Publisher
John Wiley and Sons
Year
1994
Tongue
English
Weight
691 KB
Volume
32
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A technique has been developed whereby motion can be detected in real time during the acquisition of data. This enables the implementation of an algorithm to accept or reject and reacquire data during a scan. Frames of data with motion are rejected and reacquired on the fly so that by the end of the scan, a complete motion‐free data set has been acquired. The algorithm has been implemented on several different types of sequences. Preliminary in vivo studies indicate that motion artifacts are dramatically reduced.


📜 SIMILAR VOLUMES


Analysis of residual coronary artery mot
✍ R. W. Fischer; R. M. Botnar; K. Nehrke; P. Boesiger; W. J. Manning; D. C. Peters 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 500 KB

## Abstract Coronary artery MRI methods utilize breath holds, or diaphragmatic navigators, to compensate for respiratory motion. To increase image quality and navigator (NAV) gating efficiency, slice tracking is used, with more sophisticated affine motion models recently introduced. This study asse

Self-navigated motion correction using m
✍ Edward Brian Welch; Phillip J. Rossman; Joel P. Felmlee; Armando Manduca 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 440 KB

## Abstract Interest in radial MRI (also known as projection reconstruction (PR) MRI) has increased recently for uses such as fast scanning and undersampled acquisitions. Additionally, PR acquisitions offer intrinsic advantages over standard two‐dimensional Fourier transform (2DFT) imaging with res

Reduction of motion artifacts in cine MR
✍ Jan-Ray Liao; John M. Pauly; Thomas J. Brosnan; Norbert J. Pelc 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 763 KB

## Abstract Dynamic cardiac imaging in MRI is a very challenging task. To obtain high spatial resolution, temporal resolution, and signalto‐noise ratio (SNR), single‐shot imaging is not sufficient Use of multishot techniques resolves this problem but can cause motion artifacts because of data incon

Fully automatic, retrospective enhanceme
✍ Peter Kellman; Christophe Chefd'hotel; Christine H. Lorenz; Christine Mancini; A 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 947 KB

## Abstract Real‐time imaging may be clinically important in patients with congestive heart failure, arrhythmias, or in pediatric cases. However, real‐time imaging typically has compromised spatial and temporal resolution compared with gated, segmented studies. To combine the best features of both

In vivo MRI using real-time production o
✍ Bastiaan Driehuys; Jim Pollaro; Gary P. Cofer 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 552 KB

## Abstract MR imaging of hyperpolarized (HP) nuclei is challenging because they are typically delivered in a single dose of nonrenewable magnetization, from which the entire image must be derived. This problem can be overcome with HP ^129^Xe, which can be produced sufficiently rapidly to deliver i