## Abstract A system for the real‐time analysis of functional magnetic resonance imaging (fMRI) time series is evaluated. The system exploits the advantages of parallel computing, coupled with an efficient general linear model (GLM) coefficient estimation algorithm, to overcome several issues const
Real-time black-blood MRI using spatial presaturation
✍ Scribed by Krishna S. Nayak; Pedro A. Rivas; John M. Pauly; Greig C. Scott; Adam B. Kerr; Bob S. Hu; Dwight G. Nishimura
- Publisher
- John Wiley and Sons
- Year
- 2001
- Tongue
- English
- Weight
- 219 KB
- Volume
- 13
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A real‐time interactive black‐blood imaging system is described. Rapid blood suppression is achieved by exciting and dephasing slabs outside the imaging slice before each imaging excitation. Sharp‐profiled radio frequency saturation pulses placed close to the imaging slice provide good blood suppression, even in views containing slow through‐plane flow. In vivo results indicate that this technique improves endocardial border definition during systole in real‐time cardiac wall‐motion studies. Phantom and animal results indicate that this technique nearly eliminates flow artifacts in real‐time intravascular studies. J. Magn. Reson. Imaging 2001;13:807–812. © 2001 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To measure peripheral artery function using a real‐time phase‐contrast (PC)‐MRI sequence with tailored image‐processing algorithms for flow computation. ## Materials and Methods An approach to real‐time flow measurements was developed based on two‐dimensional spatially sel
A multislice real-time imaging technique is described which can provide continuous visualization of the entire left ventricle under resting and stress conditions. Three dynamically adjustable slices containing apical, mid, and base short axis views are imaged 16 times/sec (48 images/sec), with each
## Abstract A technique has been developed whereby motion can be detected in real time during the acquisition of data. This enables the implementation of an algorithm to accept or reject and reacquire data during a scan. Frames of data with motion are rejected and reacquired on the fly so that by t
## Abstract Two‐dimensional (2D) breath‐hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three‐dimensional (3D) cardiac MR can overcome some of thes