After an introduction to Fourier NMR imaging, the effect of magnetic field inhomogeneity on image quality is discussed. The field inhomogeneity leads to a distortion of the image when the reciprocal space is sampled on an oblique plane. This effect is especially strong in echo-planar imaging (EPI),
Radial Echo-Planar Imaging
β Scribed by Afonso C. Silva; Emmanuel L. Barbier; Irving J. Lowe; Alan P. Koretsky
- Publisher
- Elsevier Science
- Year
- 1998
- Tongue
- English
- Weight
- 241 KB
- Volume
- 135
- Category
- Article
- ISSN
- 1090-7807
No coin nor oath required. For personal study only.
β¦ Synopsis
A new ultrafast magnetic resonance imaging pulse sequence named radial echo-planar imaging (rEPI) is introduced. The sequence is based on a modification of the echo-planar imaging (EPI) sequence to scan k-space radially, in an attempt to combine the speed of EPI with the benefits of radial sampling. Like in EPI, all the desired lines in k-space are scanned consecutively in opposite directions. The unique feature of this new sequence, however, is that the orientation of the readout gradient is incrementally rotated, so that all the echoes are refocused through the center of k-space. Therefore, rEPI data are acquired in a polar grid, and image reconstruction can be done either by means of filtered back-projection or by regridding the data to a Cartesian matrix followed by 2D Fourier transform. First results show that rEPI images can be acquired with the same speed and signal-to-noise ratio of EPI images. rEPI images are also shown to be less sensitive to off-resonance effects than EPI images. Further studies are underway to investigate the usefulness of rEPI for spectroscopic imaging and applications affected by motion.
π SIMILAR VOLUMES
## Abstract Rapid volumetric magnetic resonance spectroscopic imaging (MRSI) is potentially of great relevance to the diagnosis and treatment of focal cerebral diseases such as cancer and epilepsy. A strategy for volumetric multishot echoβplanar spectroscopic imaging (MEPSI) is described which allo
Cyclic J cross polarisation (CYCLCROP) is a sensitive method for the noninvasive monitoring of 13 C distributions and fluxes. The PRAWN rotating frame Hartmann-Hahn mixing sequence ameliorates problems associated with sensitivity to Hartmann-Hahn mismatch and reduces RF power deposition. The combina
A rapid automated method for reconstructing echo planar imaging (EPI) data has been developed and is shown to improve image quality by suppressing the troublesome ghost artifact. The algorithm can be applied without prior knowledge obtained from either reference scans or operator intervention. It fi