𝔖 Bobbio Scriptorium
✦   LIBER   ✦

1H Detected 13C Echo Planar Imaging

✍ Scribed by Alex.M.J. Hudson; Walter Köckenberger; Michael Heidenreich; Narayanan Chandrakumar; Rainer Kimmich; Richard Bowtell


Publisher
Elsevier Science
Year
2002
Tongue
English
Weight
280 KB
Volume
155
Category
Article
ISSN
1090-7807

No coin nor oath required. For personal study only.

✦ Synopsis


Cyclic J cross polarisation (CYCLCROP) is a sensitive method for the noninvasive monitoring of 13 C distributions and fluxes. The PRAWN rotating frame Hartmann-Hahn mixing sequence ameliorates problems associated with sensitivity to Hartmann-Hahn mismatch and reduces RF power deposition. The combination of CYCLCROP with echo planar imaging (EPI) for spatial encoding of the proton detected carbon signal allows efficient use of the available signal to be made, permitting a significant improvement in the temporal resolution of any study. We report here on some initial experiments to demonstrate the feasibility of echo planar proton detected 13 C imaging using CYCLCROP based upon the PRAWN module, including the application of the technique to the measurement of transport and accumulation of 13 C-labelled sucrose in a castor bean seedling. Two methods that can be used to eliminate the effect of the J-splitting in the EP images are presented. In addition, a fast, image-based B 1 field-mapping method which may be used to quantitatively map the low frequency RF field in a dual resonant ( 13 C/ 1 H) probe is presented. The technique utilises the above described imaging method, permitting fully quantitative, 64×64 axial field maps to be generated in about a minute.


📜 SIMILAR VOLUMES


Detection and correction of frequency in
✍ Andreas Ebel; Andrew A. Maudsley 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 320 KB

## Abstract Spectral quality in ^1^H magnetic resonance spectroscopic imaging (MRSI) critically depends on the stability of the main magnetic field. For echo‐planar MRSI implemented at 3 T, temperature variation in the passive steel shims of the magnet system can lead to a significant drift in the

Radial Echo-Planar Imaging
✍ Afonso C. Silva; Emmanuel L. Barbier; Irving J. Lowe; Alan P. Koretsky 📂 Article 📅 1998 🏛 Elsevier Science 🌐 English ⚖ 241 KB

A new ultrafast magnetic resonance imaging pulse sequence named radial echo-planar imaging (rEPI) is introduced. The sequence is based on a modification of the echo-planar imaging (EPI) sequence to scan k-space radially, in an attempt to combine the speed of EPI with the benefits of radial sampling.

Multiple-shot echo-planar imaging
✍ Hennel, Franciszek 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 399 KB

After an introduction to Fourier NMR imaging, the effect of magnetic field inhomogeneity on image quality is discussed. The field inhomogeneity leads to a distortion of the image when the reciprocal space is sampled on an oblique plane. This effect is especially strong in echo-planar imaging (EPI),

Fast 13C-glucose metabolite mapping in r
✍ Shigehiro Morikawa; Toshiro Inubushi 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 146 KB

## Abstract For fast ^13^C metabolite mapping in rat brains, ^1^H‐detected ^13^C NMR spectroscopy using gradient‐enhanced heteronuclear multiple‐quantum coherence and ^1^H echo planar spectroscopic imaging were combined. ^13^C glucose and 3‐/4‐^13^C‐Glu/Gln images of rat brain were successfully con

13C-selective, 1H-detected 2D {1H, 13C}
✍ Leszek Poppe; Herman van Halbeek 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 295 KB

## Abstract Two‐dimensional ^1^H‐detected {^1^H, ^13^C} shift correlation spectra of oligosaccharides usually suffer from low resolution in the ^13^C frequency domain. This drawback can be overcome through a simple modification of the HSQC experiment, namely by implementing a selective ^13^C 180° p