𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Rapid iterative reconstruction for echo planar imaging

✍ Scribed by David L. Foxall; Paul R. Harvey; Jian Huang


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
197 KB
Volume
42
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


A rapid automated method for reconstructing echo planar imaging (EPI) data has been developed and is shown to improve image quality by suppressing the troublesome ghost artifact. The algorithm can be applied without prior knowledge obtained from either reference scans or operator intervention. It first estimates, then improves iteratively, the parameters for a linear phase correction applied directly to the complex image data derived from odd and even echoes. The theory used to derive the criteria employed in the iteration provides insight into mechanisms that allow the process to work.


πŸ“œ SIMILAR VOLUMES


Rapid T1 mapping using multislice echo p
✍ Stuart Clare; Peter Jezzard πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 145 KB

## Abstract Determination of neurological pathology in white matter disease can be made in a semiquantitative way from __T__~1~‐ or __T__~2~‐weighted images. A higher level of quantification based on measured __T__~1~ or __T__~2~ values has been either limited to specific regions of interest or to

Tomographic reconstruction technique for
✍ Iwaki Akiyama πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 178 KB

This article proposes a tomographic reconstruction ## II. THEORY technique using divergent ultrasonic waves of a circular arc wavefront A one-dimensional thin transducer array to form the divergent which are formed by one-dimensional thin-phased array. The projecultrasonic waves was used as a pha

Iterative GRAPPA (iGRAPPA) for improved
✍ Tiejun Zhao; Xiaoping Hu πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 308 KB

## Abstract In this work an iterative reconstruction method based on generalized autocalibrating partially parallel acquisitions (GRAPPA) reconstruction is introduced. In the new method the reconstructed lines are used to reestimate and refine the weights from all the acquired data by applying the

New reconstruction technique for echo-pl
✍ Kensuke Sekihara; Hideki Kohno πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 330 KB

An image reconstruction technique for echo-planar imaging is proposed. This technique combines odd and even numbered echo signals. It is thus possible to reduce the frequency of the time-modulated gradient used in echo-planar imaging by 50%, and to reduce its amplitude by almost 50% for sinusoidal g