Quantitative Ionspray Liquid Chromatographic/Tandem Mass Spectrometric Determination of Reserpine in Equine Plasma
โ Scribed by Anderson, Melissa A.; Wachs, Timothy; Henion, Jack D.
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 350 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1076-5174
No coin nor oath required. For personal study only.
โฆ Synopsis
A method based on ionspray liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed for the determination of reserpine in equine plasma. A comparison was made of the isolation of reserpine from plasma by liquid-liquid extraction and by solid-phase extraction. A structural analog, rescinnamine, was used as the internal standard. The reconstituted extracts were analyzed by ionspray LC/MS/MS in the selected reaction monitoring (SRM) mode. The calibration graph for reserpine extracted from equine plasma obtained using liquid-liquid extraction was linear from 10 to 5000 pg ml-1 and that using solid-phase extraction from 100 to 5000 pg ml-1. The lower level of quantitation (LLQ) using liquid-liquid and solid-phase extraction was 50 and 200 pg ml-1, respectively. The lower level of detection for reserpine by LC/MS/MS was 10 pg ml-1. The intra-assay accuracy did not exceed 13% for liquid-liquid and 12% for solid-phase extraction. The recoveries for the LLQ were 68% for liquid-liquid and 58% for solid-phase extraction.