On-line capillary isoelectric focusing CIEF ᎐electrospray ionization Ž . time-of-flight mass spectrometry ESI᎐TOFMS as a two-dimensional separation Ž system is employed for high-resolution analysis of model proteins myoglobin and . -lactoglobulin and human hemoglobin variants C, S, F, and A. The fo
Quantitative evaluation of protein–protein and ligand–protein equilibria of a large allosteric enzyme by electrospray ionization time-of-flight mass spectrometry
✍ Scribed by Ayeda Ayed; Andrew N. Krutchinsky; Werner Ens; Kenneth G. Standing; Harry W. Duckworth
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 138 KB
- Volume
- 12
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
✦ Synopsis
A mass spectrometer coupling electrospray ionization with time-of-flight mass spectrometry (ESI-TOFMS) has been used to investigate the oligomeric species of Escherichia coli citrate synthase, and to determine the effect of nicotinamide adenine dinucleotide (NADH), an allosteric inhibitor of this enzyme, on the equilibrium between the oligomeric forms. An equilibrium mixture of dimers (M = 95 770 Da) and hexamers (M = 287 310 Da) was found under the conditions used (K A = 6.9 Â 10 10 M À2 ), and NADH was observed to bind selectively to the hexamer (K D = 1.1 mM), shifting the equilibrium to the latter form. The power of ESI-TOFMS to measure ions of very large mass-to-charge ratio (up to m/z $ 10 000 in this case) is shown to be a valuable tool for obtaining accurate information about compositions of noncovalent complexes and equilibrium constants. The measured constants agree with those determined by conventional means.
📜 SIMILAR VOLUMES
Capillary electrophoresis/electrospray ionization (CE/ESI) high mass accuracy time-of-flight mass spectrometry was used for the first time to characterize small proteins using peptide mapping. To identify small proteins, the intact proteins were first analyzed to obtain their average molecular weigh
We describe the coupling of a microfabricated fluidic device to an electrospray ionization (ESI) quadrupole time-of-flight mass spectrometer (QqTOFMS) for the identification of protein samples. The microfabricated devices consisted of three reservoirs connected via channels to a main capillary, whic
Fundamental concepts of high-resolution mass spectrometry as it relates to the issue of accurate mass measurements are presented. Important issues speciÐc to magnetic sector instruments, Fourier transform ion cyclotron resonance and time-of-Ñight (TOF) methods are discussed. Recent high-resolution T