โœฆ Synopsis


Fundamental concepts of high-resolution mass spectrometry as it relates to the issue of accurate mass measurements are presented. Important issues speciรc to magnetic sector instruments, Fourier transform ion cyclotron resonance and time-of-ร‘ight (TOF) methods are discussed. Recent high-resolution TOF measurements on peptides and proteins, ionized by matrix-assisted laser desorption/ionization (MALDI), are presented and discussed in terms of basic concepts important to accurate mass measurements.


๐Ÿ“œ SIMILAR VOLUMES


Characterizing DNA photo-oxidation react
โœ Bartolini, Wilmin P.; Johnston, Murray V. ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 151 KB

High-resolution mass measurements by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry were employed to characterize laser-induced oxidation of guanine in a small synthetic deoxyoligonucleotide. The oligonucleotide was exposed to high-intensity UV radiation at

Sample preparation for high throughput a
โœ Derek A. Lake; Murray V. Johnson; Charles N. McEwen; Barbara S. Larsen ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 79 KB ๐Ÿ‘ 2 views

An automated sample preparation for high throughput accurate mass determinations by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been developed. Sample preparation was performed with an automated workstation and automated mass analyses were performed

Accurate peptide sequencing by post-sour
โœ Wenjun Mo; Toshifumi Takao; Yasutsugu Shimonishi ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 153 KB ๐Ÿ‘ 2 views

Partial 18 O-labeling of peptides has been applied to post-source decay experiments in a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer. The ions which originate from the carboxyl terminus of a peptide partially retain 18 O atoms which have readily been incorporated int

The characterization of micro-organisms
โœ Kevin J. Welham; Mark A. Domin; D. Eoin Scannell; E. Cohen; David S. Ashton ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 229 KB ๐Ÿ‘ 2 views

A variety of gram-positive and gram-negative intact bacterial cells have been analysed by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) and shown to provide fingerprint mass spectra with discrete peaks being observed over the mass range from 3 to 40 kDa. The spectra show b