On-line capillary isoelectric focusing CIEF แelectrospray ionization ลฝ . time-of-flight mass spectrometry ESIแTOFMS as a two-dimensional separation ลฝ system is employed for high-resolution analysis of model proteins myoglobin and . โค-lactoglobulin and human hemoglobin variants C, S, F, and A. The fo
Capillary electrophoresis/electrospray ionization high mass accuracy time-of-flight mass spectrometry for protein identification using peptide mapping
โ Scribed by Ping Cao; Mehdi Moini
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 151 KB
- Volume
- 12
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
โฆ Synopsis
Capillary electrophoresis/electrospray ionization (CE/ESI) high mass accuracy time-of-flight mass spectrometry was used for the first time to characterize small proteins using peptide mapping. To identify small proteins, the intact proteins were first analyzed to obtain their average molecular weights with errors less than 1 Da. On-line capillary electrophoresis mass spectrometry of the tryptic digests of these small proteins was then performed to obtain the accurate molecular weights of the peptides with accuracies of approximately 10 ppm. Next, this information was used for the identification of the proteins using a protein database. It was found that high mass accuracy is an effective tool in reducing the list of most-likely proteins generated by the database. In addition, on-line collision-induced dissociation of the completely or partially resolved capillary electrophoresis peaks of the protein digests was used to unambiguously identify the sequences of these peptides. Each CE/ESI-MS analysis used only 5 nL of sample containing approximately 120 fmol of each peptide in protein digests. The results indicate that the combination of capillary electrophoresis and high resolution, high mass accuracy time-of-flight mass spectrometry is a viable option for the identification of small proteins using peptide mapping.
๐ SIMILAR VOLUMES
Chromium-gold coated fused silica emitters for electrospray ionization have been fabricated with lifetimes upwards of 100 hours. The coating on these emitters is extremely durable withstanding electrical discharges, abrasion and mechanical stress. Usable flow rates range from 30 nL/min to 1 mL/min u
We describe the coupling of a microfabricated fluidic device to an electrospray ionization (ESI) quadrupole time-of-flight mass spectrometer (QqTOFMS) for the identification of protein samples. The microfabricated devices consisted of three reservoirs connected via channels to a main capillary, whic