Capillary electrophoresis/electrospray ionization high mass accuracy time-of-flight mass spectrometry for protein identification using peptide mapping

โœ Scribed by Ping Cao; Mehdi Moini


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
151 KB
Volume
12
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

โœฆ Synopsis


Capillary electrophoresis/electrospray ionization (CE/ESI) high mass accuracy time-of-flight mass spectrometry was used for the first time to characterize small proteins using peptide mapping. To identify small proteins, the intact proteins were first analyzed to obtain their average molecular weights with errors less than 1 Da. On-line capillary electrophoresis mass spectrometry of the tryptic digests of these small proteins was then performed to obtain the accurate molecular weights of the peptides with accuracies of approximately 10 ppm. Next, this information was used for the identification of the proteins using a protein database. It was found that high mass accuracy is an effective tool in reducing the list of most-likely proteins generated by the database. In addition, on-line collision-induced dissociation of the completely or partially resolved capillary electrophoresis peaks of the protein digests was used to unambiguously identify the sequences of these peptides. Each CE/ESI-MS analysis used only 5 nL of sample containing approximately 120 fmol of each peptide in protein digests. The results indicate that the combination of capillary electrophoresis and high resolution, high mass accuracy time-of-flight mass spectrometry is a viable option for the identification of small proteins using peptide mapping.


๐Ÿ“œ SIMILAR VOLUMES


Capillary isoelectric focusingโ€“electrosp
โœ Jing Wei; Cheng S. Lee; Iulia M. Lazar; Milton L. Lee ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 88 KB ๐Ÿ‘ 2 views

On-line capillary isoelectric focusing CIEF แސelectrospray ionization ลฝ . time-of-flight mass spectrometry ESIแސTOFMS as a two-dimensional separation ลฝ system is employed for high-resolution analysis of model proteins myoglobin and . โค-lactoglobulin and human hemoglobin variants C, S, F, and A. The fo

Metallized sheathless electrospray emitt
โœ David R. Barnidge; Stefan Nilsson; Karin E. Markides; Hรฅkan Rapp; Klas Hjort ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 174 KB ๐Ÿ‘ 1 views

Chromium-gold coated fused silica emitters for electrospray ionization have been fabricated with lifetimes upwards of 100 hours. The coating on these emitters is extremely durable withstanding electrical discharges, abrasion and mechanical stress. Usable flow rates range from 30 nL/min to 1 mL/min u

Microfabricated device coupled with an e
โœ Daniel Figeys; Chris Lock; Lorne Taylor; Ruedi Aebersold ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 363 KB ๐Ÿ‘ 2 views

We describe the coupling of a microfabricated fluidic device to an electrospray ionization (ESI) quadrupole time-of-flight mass spectrometer (QqTOFMS) for the identification of protein samples. The microfabricated devices consisted of three reservoirs connected via channels to a main capillary, whic