𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Quality Control During Processing of Feta Cheese—NIR Application

✍ Scribed by Konstantinos G. Adamopoulos; Athanasia M. Goula; Heracles J. Petropakis


Publisher
Elsevier Science
Year
2001
Tongue
English
Weight
405 KB
Volume
14
Category
Article
ISSN
0889-1575

No coin nor oath required. For personal study only.

✦ Synopsis


This work examines the possibility of using near infrared (NIR) spectroscopic method for the production process control of the traditional Greek feta cheese. A NIR apparatus (Instalab 600-Dickey}John) was employed. Moisture, fat and protein determinations were selected as calibration set for the instrument. Samples were drawn from well-de"ned critical points of production. In all the samples conventional chemical methods were applied for the quantitative determination of the above ingredients. Results were compared with the respective data from NIR apparatus. All data were processed by a suitable computer program so that the calibration constants could be calculated and then stored in the apparatus. Their accuracy was veri"ed using an independent set of analyzed samples. Because the NIR apparatus used in this work was not suitable for liquid products, a novel technique was developed using &&quartz "ne granular washed and calcined GR'' (pro analysi). This technique proved to be reliable with a signi"cant accuracy. From this study it can be concluded that NIR technique can be applied successfully for the on-line quality control of the feta cheese production. The reliability, signi"cant reduction of human errors, precision and quickness of NIR spectroscopy experienced during this work, support the implementation of this method.


📜 SIMILAR VOLUMES


Quality by design, part I: Application o
✍ Simin Hassannejad Tabasi; Raafat Fahmy; Dennis Bensley; Charles O'Brien; Stephen 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 425 KB

To monitor tableting production using near infrared (NIR) spectroscopy, chemometric models were developed to analyze peak compression force, crushing strength and content uniformity. To measure tablet content uniformity, orbifloxacin tablets with drug content ranging from 60 to 90 mg were made and a

Application of Ultrasonic Waves to Quali
✍ Wokke, J. M. P. ;van der Wal, T. 📂 Article 📅 1991 🏛 John Wiley and Sons ⚖ 426 KB

Hierin bedeutet: N Zahl der MeDwertpaare. 4.3. Nachwek-, Entschidungsund Bestimmungsgrenze: 4.3.1. Mit Hilfe der Gleichung der linearen Regression der Datenpaare fiir den Wert x = 0 (z. B. Gehalt = 0) den ,Blank"-Wert Yb errechnen. 4.3.2. Aus der Rest-Standardabweichung rsd der Regressionsgleichung

Quality by design, part II: Application
✍ Simin Hassannejad Tabasi; Raafat Fahmy; Dennis Bensley; Charles O'Brien; Stephen 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 654 KB

Ammonio methacrylate copolymers are commercially available as Eudragit RL/RS; they differ in the degree of quaternary ammonium group substitution, which gives them different permeabilities. These closely related polymers can be combined in various ratios to control release rate; consequently, releas

Design and Application of Quality Contro
✍ M. Dijkman; G. Goch; C. Ament 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 148 KB

This paper presents strategies for an automated control of distortion at the operational level of a production process chain, as well as first steps towards a combined implementation in heat-treatment processes. In order to minimise the loss of production due to quality defects, the first quality co