Transient changes in the transmission of a 355 nm probe pulse through corneal tissue during 193 nm ArF laser ablation have been examined. A significant decrease in collimated transmission of the probe beam was observed for time delays between 10 ns and 1 ms after the 193 nm laser pulse. At 10 ns del
Pump and probe technique on excimer laser-induced plasmas
β Scribed by M. Aden; M. Alunovic; E.W. Kreutz
- Book ID
- 108418384
- Publisher
- Elsevier Science
- Year
- 1997
- Tongue
- English
- Weight
- 189 KB
- Volume
- 109-110
- Category
- Article
- ISSN
- 0169-4332
No coin nor oath required. For personal study only.
π SIMILAR VOLUMES
The newly-developed laser "pump-and-probe" method has been utrlized to determme the initial rotation&state distributlon of a dlatomlc product of a chemxal reaction. Cd('Pt) + Hz -c CdH (u = 0, IV) f H. The distnbution closely approuimares a Boltzmann dlstnbutlon uxth Teff i= 5000 K.