๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Pump/probe transmission measurements of corneal tissue during excimer laser ablation

โœ Scribed by G. H. Pettit; M. N. Ediger


Publisher
John Wiley and Sons
Year
1993
Tongue
English
Weight
464 KB
Volume
13
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

โœฆ Synopsis


Transient changes in the transmission of a 355 nm probe pulse through corneal tissue during 193 nm ArF laser ablation have been examined. A significant decrease in collimated transmission of the probe beam was observed for time delays between 10 ns and 1 ms after the 193 nm laser pulse. At 10 ns delay the collimated probe transmission was 70% of the preablation level. Minimum collimated transmission (40%) was observed at 30 p s delay. Transmitted probe examination by both diode array and integrating sphere measurements indicate the observed attenuation is due to scattering of the incident probe beam and not due to absorption. The significant scattering at nanosecond delay times suggests onset of the ablation process during the ArF pulse. Scattering therefore may affect the deposition of the 193 nm radiation in the ablation target. o 1993 Wiley-Liss, hc.*


๐Ÿ“œ SIMILAR VOLUMES


Transmission of corneal collagen during
โœ M. N. Ediger; G. H. Pettit; R. P. Weiblinger; C. H. Chen ๐Ÿ“‚ Article ๐Ÿ“… 1993 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 667 KB

The time-resolved transmission of collagen films and 10-pm sections of bovine cornea during ArF laser ablation has been investigated. The film studies were performed on thin layers of extracted bovine corneal collagen, the principal chromophore in 193 nm photoablation. Transmission measurements were

Dynamics of ablation plume particles gen
โœ D. W. Hahn; M. N. Ediger; G. H. Pettit ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 546 KB

Background and Objective: Although the empirical characteristics of ArF excimer laser corneal ablation have been well documented, the exact ablation mechanisms are not well understood. The present paper reports a quantitative analysis of corneal ablation plumes using in situ time resolved laser ligh

Effects of laser repetition rate on corn
โœ Leia M. Shanyfelt; Pamela L. Dickrell; Henry F. Edelhauser; David W. Hahn ๐Ÿ“‚ Article ๐Ÿ“… 2008 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 376 KB

## Abstract ## Background and Objective The goal of the present work is to assess whether bovine corneal ablations generated at laser repetition rates of up to 400 Hz are comparable to ablations performed at rates consistent with current clinical laser systems. ## Study Design/Materials and Metho

Measurement of the surface temperature o
โœ Miya Ishihara; Tsunenori Arai; Shunichi Sato; Yuji Morimoto; Minoru Obara; Makot ๐Ÿ“‚ Article ๐Ÿ“… 2002 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 130 KB

## Abstract ## Background and Objective The purpose of this work was to develop a temperature measurement system with a nanosecond time response to monitor the transient temperature of the corneal surface during laser refractive surgery. ## Materials and Methods Thermal radiation from the surfac